Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
2880 N BALBOA AV
Address NEW:
2880 N BALBOA AV
Apply Date:
06/21/2004
Applicant:
H F H TUCSON
Description:
SFR:TD#16-05-90
Contractors:
  • H F H TUCSON

Permit Reviews

Permit Number - T04CM02840
Permit Status: C of o
Permit Description: SFR:TD#16-05-90
Start Date Submittal Complete Date Status  
06/21/2004 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 06/22/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM02840
Permit Status: C of o
Permit Description: SFR:TD#16-05-90
Total Outstanding Activity Conditions - 1
Date Name
06/21/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T04CM02840
Permit Description: SFR:TD#16-05-90
Total Completed Inspections - 23
Date Description Inspector Results Comments
07/02/2004 PLUMBING - ROUGH, SOIL EDURAZO Approved IVRS - Inspection :*
07/07/2004 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection :*/ 1) YOU NEED TO HAVE PROPERTY PINS EXPOSED. THESE ? YARD SETBACKS ARE TOO CLOSE, VERY EASY TO MAKE A MISTAKE. THIS UNIT HAD 5' OFF SET PINS
07/07/2004 ELECTRIC - UFER RFREIDIN Approved IVRS - Inspection :*
07/07/2004 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection :*
08/06/2004 PLUMBING - SEWER HCS CONNECT BSTEVENS Approved IVRS - Inspection :*
08/12/2004 ELECTRIC - TEMPORARY SERVICE BSTEVENS Approved IVRS - Inspection :*
08/12/2004 ELECTRIC - CABLE DROP BSTEVENS Approved IVRS - Inspection :*
08/13/2004 TEP CLEARANCE - AM JKOZUCH Approved
10/01/2004 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection :*/ 1) OK TO DRY IN GABLE ROOF ONLY, FRONT NOT SHEATHED 2) FINISH VERTICAL WALL SHEATHING DETAIL (1) ENDS OF TRUSSES NORTH WALL 3) NEED CMU INTEGRA (SPECIAL INSPECTION REPORTS) 4) 3 PT TRUSSES TURNED END FOR END 5) A. BOLTS 12" FROM END OF SPLICE
10/08/2004 ROOF NAILING JRIVA Approved IVRS - Inspection :* ALL ? STORE ROOM ( WEST WALL) OK TO DRY IN HOUSE.
11/03/2004 PLUMBING - YARD WTR LINE/TEST JRIVA Approved IVRS - Inspection :*
01/24/2005 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
01/26/2005 MECHANICAL - INTERMEDIATE HLEYVA Approved IVRS - Inspection :*
01/26/2005 PLUMBING - INTERMEDIATE HLEYVA Approved IVRS - Inspection :*
01/26/2005 FRAMING HLEYVA Approved IVRS - Inspection :*
02/09/2005 STUCCO MESH BSTEVENS Approved IVRS - Inspection :* APPROVED
02/17/2005 SHEET ROCK NAILING RCAMACHO Approved IVRS - Inspection :*
06/25/2005 BUILDING - FINAL DQUINN Approved IVRS - Inspection :*
06/25/2005 U VALUE FOR WINDOW DQUINN Approved IVRS - Inspection :*
06/25/2005 MECHANICAL - FINAL DQUINN Approved IVRS - Inspection :*
06/25/2005 PLUMBING - FINAL DQUINN Approved IVRS - Inspection :*
06/25/2005 ELECTRIC - FINAL DQUINN Approved IVRS - Inspection :*
12/27/2005 PERMIT FINALED LJACKSON Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
C OF O_01-03-2006.TIF CERT OF OCC VIEW
SITE PLAN_06-22-2004.TIF CONSTRPLANS VIEW