Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
2862 N BALBOA AV
Address NEW:
2862 N BALBOA AV
Apply Date:
06/21/2004
Applicant:
H F H TUCSON
Description:
SFR:TD#16-05-90
Contractors:
  • H F H TUCSON

Permit Reviews

Permit Number - T04CM02837
Permit Status: C of o
Permit Description: SFR:TD#16-05-90
Start Date Submittal Complete Date Status  
06/21/2004 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 06/22/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM02837
Permit Status: C of o
Permit Description: SFR:TD#16-05-90
Total Outstanding Activity Conditions - 1
Date Name
06/21/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T04CM02837
Permit Description: SFR:TD#16-05-90
Total Completed Inspections - 23
Date Description Inspector Results Comments
07/07/2004 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection :*/ 1) NEED 5 POUND = 10 MINS AIR TEST
07/12/2004 ELECTRIC - UFER BSTEVENS Approved IVRS - Inspection :*
07/12/2004 BUILDING PRE-SLAB BSTEVENS Approved IVRS - Inspection :*
07/12/2004 EXCAVATION/LAYOUT REBAR & ZON BSTEVENS Approved IVRS - Inspection :*
08/12/2004 PLUMBING - SEWER HCS CONNECT BSTEVENS Approved IVRS - Inspection :*
08/12/2004 ELECTRIC - TEMPORARY SERVICE BSTEVENS Approved IVRS - Inspection :*
08/12/2004 ELECTRIC - CABLE DROP BSTEVENS Approved IVRS - Inspection :*
08/13/2004 TEP CLEARANCE - AM JKOZUCH Approved
10/01/2004 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved 1) OK MAIN ROOF, STILL WORKING ON FRONT PORCHES AND ENTRY 2) ADD STUD REAR WALL, MARKED ON FLOOR, AND SOUTH WALL 3) NO INSP. ENTERED FOR CMU WALLS INTEGRA SPECIAL INSPECTION REPORT 4) SHIM ALL 3 PT TRUSSES 5) AT INTERMEDIATE CHECK TRUSS DRAWINGS FOR BEARING 6) ANCHOR BOLTS WITHIN 12" OF PLATE SPLICE 7) WILL NEED 5/8 DRYWALL AT OVER HANG SOFFITS 8) NEED TRUSS DRAWINGS 9) SHEATH TRUSS ENDS 1/A3.3 10) CHECK AB'S PIPES AT EXTERIOR PLATES FOR NAILS
10/07/2004 ROOF NAILING IVR USER Approved IVRS - AP canceled
11/03/2004 PLUMBING - YARD WTR LINE/TEST JRIVA Approved IVRS - Inspection :*
02/25/2005 MECHANICAL - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
02/25/2005 PLUMBING - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
02/25/2005 ELECTRIC - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
02/25/2005 FRAMING DQUINN Approved IVRS - Inspection :*
03/02/2005 U VALUE FOR WINDOW JRIVA Approved IVRS - Inspection :*
03/02/2005 STUCCO MESH JRIVA Approved IVRS - Inspection :*
03/15/2005 SHEET ROCK NAILING RCAMACHO Approved IVRS - Inspection :*
11/30/2005 MECHANICAL - FINAL ROHAVER Approved IVRS - Inspection :*
11/30/2005 PLUMBING - FINAL ROHAVER Approved IVRS - Inspection :*
11/30/2005 ELECTRIC - FINAL ROHAVER Approved IVRS - Inspection :*
11/30/2005 BUILDING - FINAL ROHAVER Approved IVRS - Inspection :*
05/31/2006 PERMIT FINALED LJACKSON Approved