Permit Details

Status:
Final
Type:
COMMERCIAL NEW
Address NEW:
8110 S HOUGHTON RD
Apply Date:
06/07/2004
Applicant:
KURT FRIMODIG
Description:
NEW SHELL RETAIL 60' x160' SHELL BUILDING , MASONRY W/ TRUSS ROOF
Architects:
  • KUBICEK, ROBERT W ARCHITECTS & ASSOCIATES
Contractors:
  • RIO WEST DEVELOPMENT AND CONSTRU

Permit Reviews

Permit Number - T04CM02545
Permit Status: Final
Permit Description: NEW SHELL RETAIL 60' x160' SHELL BUILDING , MASONRY W/ TRUSS ROOF
Start Date Submittal Complete Date Status  
06/07/2004 PLANS OK TO SUBMIT - 3RD PARTY 06/07/2004 COMPLETED Review Details
06/07/2004 3RD PARTY REVIEW-COMMERCIAL 09/29/2004 COMPLETED Review Details
08/08/2005 REVISION 08/10/2005 COMPLETED Review Details
08/10/2005 POST 3RD PARTY REVIEW 11/17/2005 COMPLETED Review Details
09/29/2004 POST 3RD PARTY REVIEW 10/15/2004 COMPLETED Review Details
10/18/2004 RESUBMITTAL 12/01/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM02545
Permit Status: Final
Permit Description: NEW SHELL RETAIL 60' x160' SHELL BUILDING , MASONRY W/ TRUSS ROOF
Total Outstanding Activity Conditions - 1
Date Name
06/07/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04CM02545
Permit Description: NEW SHELL RETAIL 60' x160' SHELL BUILDING , MASONRY W/ TRUSS ROOF
Total Completed Inspections - 39
Date Description Inspector Results Comments
12/17/2004 ELECTRIC - UFER RSUBA Approved IVRS - Inspection :*
12/22/2004 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection :*
12/30/2004 STEM WALL/RETAINING WALL LHANLY Approved IVRS - Inspection :*
01/27/2005 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :* PIPE WRAPS OK
04/05/2005 REINFORCED MASONRY PRE-GROUT LHANLY Approved IVRS - Inspection :*
05/04/2005 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
05/04/2005 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
06/06/2005 PLUMBING - YARD WTR LINE/TEST TRINIVJR Approved IVRS - Inspection :* 1) 2" YARD WATER LINE FROM METER TO BLDG. SERVICE IS OK. 2) OK TO BACKFILL TRENCH.
06/08/2005 PLUMBING - ROOF DRAINS RRICH Approved IVRS - Inspection :*
06/08/2005 FRAMING LHANLY Approved IVRS - Inspection :*
06/08/2005 PLUMBING - ROOF DRAINS TRINIVJR Approved IVRS - Inspection :* 1) OVERHEAD WATER DISTRIBUTION IS OK. 2) DWV AIR TEST IS OK. 3) R.W.L WATER TEST IS OK EXCEPT CENTER PRIMARY R.W.C REQUIRES WATER TEST.
06/08/2005 PLUMBING - ABOVE CEILING TRINIVJR Approved IVRS - Inspection :*
06/08/2005 PLUMBING - INTERMEDIATE TRINIVJR Approved IVRS - Inspection :*
06/20/2005 STUCCO MESH LHANLY Approved IVRS - Inspection :*
07/15/2005 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection :*
07/15/2005 ROOF NAILING LHANLY Approved IVRS - Inspection :*
08/04/2005 ELECTRIC - UNDERGROUND RSUBA Approved IVRS - Inspection :*
ELEC. & PHONE SECONDARY
08/04/2005 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection :*
08/05/2005 ELECTRIC - INTERMEDIATE RSUBA Approved IVRS - Inspection :*
1) 2-8' X 5/8" ROD WITH 3/0 CU.
09/23/2005 ELECTRIC - PROGRESS RSUBA Approved IVRS - Inspection :*
09/26/2005 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
09/26/2005 ELECTRIC - FINAL RSUBA Approved IVRS - Inspection :*
09/26/2005 ELECTRIC - ABOVE CEILING RSUBA Approved IVRS - Inspection :*
09/26/2005 BUILDING ABOVE CEILING LHANLY Approved IVRS - Inspection :*
09/29/2005 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
1) UNIT #102 PROVIDE EXHAUST DUCT
2) OK FOR CEILING TILES ALL UNITS
3) WILL CHECK MINI SPLIT SYSTEMS ON FINAL
4) CONDENSATE CANNOT DRIP ONTO SIDEWALK
5) HAVE YOUR ENGINEER DESIGN A MEANS OF TERMINATION
10/11/2005 TEP CLEARANCE - PM JKOZUCH Approved HOUSE PANEL # 7
10/13/2005 U VALUE FOR WINDOW LHANLY Approved IVRS - Inspection :*
10/13/2005 BUILDING - PROGRESS LHANLY Approved IVRS - Inspection :*
10/21/2005 FIRE - FINAL LTHOMAS Approved
10/21/2005 FIRE SPKLR - FINAL LTHOMAS Approved
10/21/2005 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
10/25/2005 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
11/16/2005 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*OK FOR FINAL
11/16/2005 MECHANICAL - PROGRESS JMILITEL Approved IVRS - Inspection :*
11/21/2005 BUILDING - FINAL LHANLY Approved IVRS - Inspection :*COMPLETE METAL ROOF & INSTALL H.C PARKING SIGNS
PROVIDE ALL OTHER FINAL INSPECTIONS REPORTS
03/24/2006 OUTDOOR LIGHTING FINAL RSUBA Approved IVRS - Inspection :*
MARK 990-2960
06/21/2006 EXT METAL CLIPS/EXT SHEATHING GDABBS Approved
06/21/2006 ELECTRIC - TEMP POWER FOR TEST RSUBA Approved
06/07/2007 ENGINEERING - FINAL NKALAHAR Approved