Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
05/11/2004
Applicant:
MONTEREY HOMES CONSTRUCTION INC *C
Description:
SFR:TD#15-96-96
Contractors:
  • MONTEREY HOMES CONSTRUCTION INC *C

Permit Reviews

Permit Number - T04CM02114
Permit Status: C of o
Permit Description: SFR:TD#15-96-96
Start Date Submittal Complete Date Status  
05/11/2004 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 05/11/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM02114
Permit Status: C of o
Permit Description: SFR:TD#15-96-96
Total Outstanding Activity Conditions - 1
Date Name
05/11/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T04CM02114
Permit Description: SFR:TD#15-96-96
Total Completed Inspections - 25
Date Description Inspector Results Comments
06/09/2004 PLUMBING - ROUGH, SOIL WNORTH Approved IVRS - Inspection :*
06/17/2004 ELECTRIC - UFER WNORTH Approved IVRS - Inspection :*
06/17/2004 BUILDING PRE-SLAB WNORTH Approved IVRS - Inspection :*
06/17/2004 EXCAVATION/LAYOUT REBAR & ZON WNORTH Approved IVRS - Inspection :*
06/30/2004 EXT METAL CLIPS/EXT SHEATHING WNORTH Approved IVRS - Inspection :*
07/02/2004 ROOF NAILING WNORTH Approved IVRS - Inspection :*
07/27/2004 STUCCO MESH JRIVA Approved IVRS - Inspection :*
07/27/2004 PLUMBING - GAS PRESSURE TEST JRIVA Approved IVRS - Inspection :*
07/27/2004 MECHANICAL - INTERMEDIATE JRIVA Approved IVRS - Inspection :*
07/27/2004 PLUMBING - INTERMEDIATE JRIVA Approved IVRS - Inspection :*
07/27/2004 ELECTRIC - INTERMEDIATE JRIVA Approved IVRS - Inspection :*
07/27/2004 FRAMING JRIVA Approved IVRS - Inspection :*
07/27/2004 U VALUE FOR WINDOW JRIVA Approved IVRS - Inspection :*
08/05/2004 SHEET ROCK NAILING WNORTH Approved IVRS - Inspection :*
08/25/2004 PLUMBING - SEWER HCS CONNECT WNORTH Approved IVRS - Inspection :*
09/29/2004 ELECTRIC - TEMPORARY SERVICE WNORTH Approved IVRS - Inspection :*
09/29/2004 ELECTRIC - CABLE DROP WNORTH Approved IVRS - Inspection :*
09/30/2004 TEP CLEARANCE - AM JKOZUCH Approved ECO
11/01/2004 BUILDING - FINAL WNORTH Approved IVRS - Inspection :*
11/01/2004 OUTDOOR LIGHTING FINAL WNORTH Approved IVRS - Inspection :*
11/01/2004 MECHANICAL - FINAL WNORTH Approved IVRS - Inspection :*
11/01/2004 PLUMBING - FINAL WNORTH Approved IVRS - Inspection :*
11/01/2004 ELECTRIC - FINAL WNORTH Approved IVRS - Inspection :*
11/01/2004 PLUMBING - YARD WTR LINE/TEST WNORTH Approved IVRS - Inspection :*
11/02/2004 PERMIT FINALED JWEATHER Approved