Permit: T04CM01643
Permit Details
Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
29 N MELWOOD AV #02
Address NEW:
29 N MELWOOD AV #02
Apply Date:
04/09/2004
Applicant:
GROVES GORDON S & JULIA M CP/RS
Description:
NEW SFR
Outstanding Activity Conditions
Permit Number - T04CM01643
Permit Status: C of o
Permit Description: NEW SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/09/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T04CM01643
Permit Description: NEW SFR
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/05/2004 | PLUMBING - ROUGH, SOIL | ROHAVER | Approved | IVRS - Inspection :* |
| 08/11/2004 | BUILDING PRE-SLAB | ROHAVER | Approved | IVRS - Inspection :* |
| 08/11/2004 | EXCAVATION/LAYOUT REBAR & ZON | ROHAVER | Approved | IVRS - Inspection :* |
| 11/03/2004 | EXT METAL CLIPS/EXT SHEATHING | ROHAVER | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED COPY OF STRAW BALE CODE 2) LET BALES SETTLE, TIGHTEN POST TENSION RODS-WASHER NUTS 3) FILL IN SOLIDLY OVER HEADERS ON BEARING WALLS 4) USE PROPER NAILS FOR CONNECTORS 5) PLANS ARE ILLEGIBLE-RESUBMIT LEGIBLE COPY FOR APPROVAL 6) SHIM I-JOISTS AT BEARING TO KEEP BOX BEAM LEVEL AND PLUM (TWISTING OUT OF PLUM NOW) |
| 11/03/2004 | ROOF NAILING | ROHAVER | Approved | IVRS - Inspection :* |
| 04/15/2005 | PLUMBING - SEWER HCS CONNECT | ROHAVER | Approved | IVRS - Inspection :* |
| 06/07/2005 | PLUMBING - GAS PRESSURE TEST | ROHAVER | Approved | IVRS - Inspection :* |
| 06/07/2005 | FRAMING | ROHAVER | Approved | IVRS - Inspection :* |
| 06/27/2005 | MECHANICAL - INTERMEDIATE | ROHAVER | Approved | IVRS - Inspection :* |
| 07/08/2005 | ELECTRIC - INTERMEDIATE | ROHAVER | Approved | IVRS - Inspection :* |
| 07/08/2005 | SHEET ROCK NAILING | ROHAVER | Approved | IVRS - Inspection :* |
| 07/27/2005 | U VALUE FOR WINDOW | ROHAVER | Approved | IVRS - Inspection :* |
| 08/24/2005 | ELECTRIC - CABLE DROP | ROHAVER | Approved | IVRS - Inspection :* CLEAR, ECO |
| 08/24/2005 | ELECTRIC - TEMPORARY SERVICE | ROHAVER | Approved | IVRS - Inspection :* 1) CLEAR 2) ECO |
| 08/25/2005 | TEP CLEARANCE - AM | FGREER | Approved | ECO CLEARED BY OHAVER |
| 09/02/2005 | PLUMBING - INTERMEDIATE | ROHAVER | Approved | IVRS - Inspection :* |
| 09/06/2005 | PLUMBING - GAS PRESS TEST FNL | CTREVILL | Approved | IVRS - Inspection :* INSTALL GAS TO H2O HEATER AND PTR LINE TO EXTERIOR OF CABINET |
| 09/09/2005 | ELECTRIC - UFER | ROHAVER | Approved | |
| 09/09/2005 | STUCCO MESH | ROHAVER | Approved | IVRS - Inspection :* |
| 09/09/2005 | MECHANICAL - FINAL | ROHAVER | Approved | IVRS - Inspection :* |
| 09/09/2005 | PLUMBING - FINAL | ROHAVER | Approved | IVRS - Inspection :* |
| 09/09/2005 | ELECTRIC - FINAL | ROHAVER | Approved | IVRS - Inspection :* |
| 09/09/2005 | BUILDING - FINAL | ROHAVER | Approved | IVRS - Inspection :* |
| 09/12/2005 | PERMIT FINALED | CFRAKER | Approved |