Permit: T04CM00115
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
1138 N WILSON AV
Address NEW:
1138 N WILSON AV
Apply Date:
01/12/2004
Applicant:
CHRIS SUGAR
Description:
ADDITION:CARPORT/REMODEL 2ND FLOOR
Outstanding Activity Conditions
Permit Number - T04CM00115
Permit Status: Expired
Permit Description: ADDITION:CARPORT/REMODEL 2ND FLOOR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/12/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T04CM00115
Permite Description: ADDITION:CARPORT/REMODEL 2ND FLOOR
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| STUCCO MESH | N/A | Not Inspected | ||
| ELECTRIC - UFER | N/A | Not Inspected | ||
| 07/30/2004 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) HANDRAIL REQUIRED ON STAIRWAY 2) GFCI OUTLET IN 2ND FLOOR BATH MUST BE ADJACENT TO LAVATORY 3) INSTALL REMAINING LIGHT FIXTURES |
| 07/30/2004 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 07/30/2004 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 07/30/2004 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
Completed Inspections
Permit Status: Expired
Permit Number: T04CM00115
Permit Description: ADDITION:CARPORT/REMODEL 2ND FLOOR
Total Completed Inspections - 9
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/28/2004 | BUILDING PRE-SLAB | BSTEVENS | Approved | IVRS - Inspection : The under slab plumbing is not per code.| 315* |
| 04/28/2004 | EXCAVATION/LAYOUT REBAR & ZON | BSTEVENS | Approved | IVRS - Inspection : The under slab plumbing is not per code.| 315* |
| 05/21/2004 | PLUMBING - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection :* |
| 05/21/2004 | ROOF NAILING | BSTEVENS | Approved | IVRS - Inspection :* |
| 06/04/2004 | ELECTRIC - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection :* |
| 06/08/2004 | MECHANICAL - INTERMEDIATE | FGREER | Approved | IVRS - Inspection :* |
| 06/08/2004 | U VALUE FOR WINDOW | FGREER | Approved | IVRS - Inspection :* |
| 06/11/2004 | FRAMING | BSTEVENS | Approved | IVRS - Inspection :* |
| 06/30/2004 | SHEET ROCK NAILING | ROHAVER | Approved | IVRS - Inspection :* |