Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
MULTI FAMILY OTHER
Address NEW:
2525 S TREAT AV #01
Apply Date:
12/09/2003
Applicant:
A S B PLUMBING
Description:
PLUMBING:RELOC WATER HEATER & GAS LINE
Contractors:
  • A S B PLUMBING

Permit Reviews

Permit Number - T03PL02050
Permit Status: Final
Permit Description: PLUMBING:RELOC WATER HEATER & GAS LINE
Start Date Submittal Complete Date Status  
12/22/2003 PLUMBING 12/22/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03PL02050
Permit Status: Final
Permit Description: PLUMBING:RELOC WATER HEATER & GAS LINE
Total Outstanding Activity Conditions - 1
Date Name
12/09/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T03PL02050
Permit Description: PLUMBING:RELOC WATER HEATER & GAS LINE
Total Completed Inspections - 4
Date Description Inspector Results Comments
12/24/2003 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection 0000*/ 10 PSI PRESSURE TEST APPROVED FROM METER TO [1] WTR HTR AND [1] WALL FURNACE ONLY. HOSE BIB AT SERVICE REQUIRES VACUUM BREAKER. GAS PIPING REQUIRES BONDING. PLEASE CORRECT AND RECALL FOR FINAL AND GAS CARD.
12/30/2003 PERMIT FINALED RRICH Approved
12/30/2003 PLUMBING - FINAL RRICH Approved IVRS - Inspection 0000*/ ALL CORRECTIONS MADE. GAS CARD DROPPED AT METER. S.W. GAS 889-1888
12/30/2003 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW