Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Apply Date:
10/17/2003
Applicant:
CUMMINGS PLUMBING INC , *C
Description:
REPLACE:GAS LINE/WATER HEATER (APA)
Contractors:
  • CUMMINGS PLUMBING INC , *C

Outstanding Activity Conditions

Permit Number - T03PL01750
Permit Status: Final
Permit Description: REPLACE:GAS LINE/WATER HEATER (APA)
Total Outstanding Activity Conditions - 1
Date Name
10/17/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T03PL01750
Permit Description: REPLACE:GAS LINE/WATER HEATER (APA)
Total Completed Inspections - 3
Date Description Inspector Results Comments
10/23/2003 PLUMBING - FINAL RRICH Approved IVRS - Inspection 0000*/ RELOCATED WATER HEATER TO EXTERIOR. NEW 3/4" GAS LINE FROM METER TO WATER HEATER APP. 10' 10 PSI TEST IS OK. OLD GAS IN INTERIOR CHANGED SERVICE ONLY STOVE WITH NEW APPROVED VALVE. CONTRACTOR TO SOAP TEST ALL NEW TIE IN PIECES ON GAS AT METER AT TIME OF GAS TURN ON. NO GAS CARD REQUIRED.
10/23/2003 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection 0000*
10/24/2003 PERMIT FINALED RRICH Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW