Permit: T03PL00220
Permit Details
Apply Date:
01/31/2003
Applicant:
TLC PLUMBING *P *C
Description:
WATER HEATER:REPLACEMENT APA
Contractors:
- TLC PLUMBING *P *C
Outstanding Activity Conditions
Permit Number - T03PL00220
Permit Status: Expired
Permit Description: WATER HEATER:REPLACEMENT APA
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/31/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T03PL00220
Permite Description: WATER HEATER:REPLACEMENT APA
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/03/2003 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection 0999* 1.) MUST REMOVE ASBESTOS FLU VENT AND INSTALL NEW DBL WALL FLU VENT & CAP. 2.) MUST REPLACE GAS SHUT OFF VALVE WITH AGA OR CSA APPROVED VALVE. 3.) P & T DRAIN HAS NEGATIVE PITCH. 4.) MUST PROVIDE FRESH AIR COMBUSTION WITH 2 10 X 10 LOUVER GRILLS ON DOOR. |