Permit: T03ME00722
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
1218 E BLACKLIDGE DR
Address NEW:
1218 E BLACKLIDGE DR
Apply Date:
12/11/2003
Applicant:
D AND H AIR CONDITIONING CO,*C
Description:
MECHANICAL:SPLIT SYSTEM APA
Contractors:
- D AND H AIR CONDITIONING CO,*C
Outstanding Activity Conditions
Permit Number - T03ME00722
Permit Status: Expired
Permit Description: MECHANICAL:SPLIT SYSTEM APA
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/11/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T03ME00722
Permite Description: MECHANICAL:SPLIT SYSTEM APA
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/18/2003 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection 0999*/ 1) CLAMP ROMEX CONNECTOR ONTO ELEC. CORD FOR FURNACE. 2) PROVIDE HOSE CLAMP ON CONDENSATE PUMP. HOOK UP OVERFLOW SENSOR ON PUMP. 3) PROVIDE PROTECTION FROM ABRASION WHERE SUCTION LINE ENTERS EVAP COIL. 4) LABEL CIRCUIT BREAKER FOR CONDENSOR. RECALL FOR INSP. |