Permit: T03ME00649
Permit Details
Apply Date:
11/13/2003
Applicant:
D T COOLING AND HEATING INC,*C
Description:
REPLACE:A/C UNIT (APA)
Contractors:
- D T COOLING AND HEATING INC,*C
Outstanding Activity Conditions
Permit Number - T03ME00649
Permit Status: Expired
Permit Description: REPLACE:A/C UNIT (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/13/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T03ME00649
Permite Description: REPLACE:A/C UNIT (APA)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/28/2003 | MECHANICAL - FINAL | N/A | Partial Approval | IVRS - Inspection 0000* 1) PROVIDE SLEEVE REAR OF SWITCH INTO UNIT ELIMINATE SHARP OPENING. 2) CANNOT TERMINATE CONDENSATE INTO WET SEWER VENT OPENINGS. 3) BE SURE TO PAINT PVC PIPING EXPOSED TO SUN. |