Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
1230 N CAMINO SECO
Apply Date:
07/15/2003
Applicant:
G T R HEATING AND AIR COND,*C
Description:
REPLACE:HEAT PUMP 5 TON (APA)
Contractors:
  • G T R HEATING AND AIR COND,*C

Outstanding Activity Conditions

Permit Number - T03ME00386
Permit Status: Expired
Permit Description: REPLACE:HEAT PUMP 5 TON (APA)
Total Outstanding Activity Conditions - 1
Date Name
07/15/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T03ME00386
Permite Description: REPLACE:HEAT PUMP 5 TON (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
07/24/2003 MECHANICAL - FINAL N/A Denied IVRS - Inspection 0999*/ 1) A LOCK NUT MUST BE USED ON THE NIPPLE CONNECTING THE ELEC. FITTING TO THE CIRCUIT PANEL. USE A BUSHING ON THE CONDUIT THAT PENETRATES THE ROOF TO PROTECT WIRE FROM ABRASION. 2) YOU CAN ONLY TERMINATE CONDENSATE INTO A SEWER VENT IF THERE IS NO WAY TO GET IT TO THE GROUND. RE-CALL FOR INSPECTION.