Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
4774 E ANDREW ST
Address NEW:
4774 E ANDREW ST
Apply Date:
06/24/2003
Applicant:
D AND H AIR CONDITIONING CO,*C
Description:
AIR COND & FURNACE:
Contractors:
  • D AND H AIR CONDITIONING CO,*C

Outstanding Activity Conditions

Permit Number - T03ME00345
Permit Status: Expired
Permit Description: AIR COND & FURNACE:
Total Outstanding Activity Conditions - 1
Date Name
06/24/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T03ME00345
Permite Description: AIR COND & FURNACE:
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
07/21/2003 MECHANICAL - FINAL N/A Partial Approval IVRS - Inspection 0000*/ 1) INSULATION ON REFER LINES NOT STICKING AT SEAMS AND JOINTS. ISOLATE BARE COPPER FROM STEEL STRAPS 2) YOU CANNOT USE SCHEDULE 40 PVC ON A WATER HEATER T & P DRAIN AND MUST BE SEPERATE FROM THE CONDENSATE DRAIN. RECALL FOR INSPECTION

Documents

File Name Document Type  
None DOCUMENTS VIEW