Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Closed
Type:
SINGLE FAMILY OTHER
Address NEW:
6120 E HAWTHORNE ST
Apply Date:
03/31/2003
Applicant:
MEHL ELECTRIC SERVICE INC,*C
Description:
UPGRADE:ELECTRIC (APA)
Contractors:
  • MEHL ELECTRIC SERVICE INC,*C

Outstanding Activity Conditions

Permit Number - T03EL00609
Permit Status: Closed
Permit Description: UPGRADE:ELECTRIC (APA)
Total Outstanding Activity Conditions - 1
Date Name
03/31/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Closed
Permit Number: T03EL00609
Permite Description: UPGRADE:ELECTRIC (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
04/14/2003 ELECTRIC - FINAL N/A Denied IVRS - Inspection 0999*
1.) USE APPROVED WIRING METHODS TO TERMINATE FLEX CONDUIT ALSO NM CABLE NOT TO BE RUN IN A COMPLETE RACEWAY SYSTEM.
2.) PLEASE VERIFY GAS BONDING.
3.) A PERMANET METAL ADDRESS LABEL IS NEEDED.
4.) PLEASE IDENTIFY NEUTRAL CLOSER TO WETHER HEAD.
5.) NEW OUTDOOR RECEPTACLES TO BE GFCI PROTECTED.
6.) NEED ACCESS TO INTERIOR TO CHECK NEW OUTLETS INSTALLED.