Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address NEW:
1006 E KENTUCKY ST
Apply Date:
12/15/2003
Applicant:
HERNANDEZ ARTURO B
Description:
ADDITION:PORCH T03VL00941

Outstanding Activity Conditions

Permit Number - T03CM05772
Permit Status: Final
Permit Description: ADDITION:PORCH T03VL00941
Total Outstanding Activity Conditions - 1
Date Name
12/15/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T03CM05772
Permit Description: ADDITION:PORCH T03VL00941
Total Completed Inspections - 7
Date Description Inspector Results Comments
09/14/2004 FRAMING AMATHIES Approved IVRS - Inspection :
See detailed listing on site.| 999*
09/14/2004 BUILDING PRE-SLAB AMATHIES Approved IVRS - Inspection :
See detailed listing on site.| 999*
09/14/2004 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved IVRS - Inspection :
See detailed listing on site.| 999*
10/08/2004 BUILDING - FINAL FGREER Approved IVRS - Inspection :*
10/19/2004 REINFORCED MASONRY PRE-GROUT JRIVA Approved IVRS - Inspection :*/ 1) WE CANNOT APPROVE FRAME UNTIL FOOTINGS AND FOUNDATION ARE APPROVED PROVIDE PROOF THAT FOUNDATION IS 12" BELOW GRADE 2) PLAN IS INCORRECT CARPORT BUILT ON PROPERTY LINE REQUIRES 2 HR FIRE WALL. HAVE NEW DESIGN APPROVED BY CITY OF TUCSON 3) UNTREATED WOOD POSTS CANNOT BE IN CONCRETE. MUST HAVE POST BASE WITH 1" SEPERATION
10/19/2004 ROOF NAILING JRIVA Approved IVRS - Inspection :*
08/02/2005 PERMIT FINALED LJACKSON Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW