Permit: T03CM05702
Permit Details
Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
1832 W CHARDONNAY DR
Address NEW:
1832 W CHARDONNAY DR
Apply Date:
12/09/2003
Applicant:
JOSE MERCADO
Description:
ADDITION:BEDROOM
Permit Reviews
Permit Number - T03CM05702
Permit Status: Final
Permit Description: ADDITION:BEDROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/09/2003 | RESIDENTIAL BLDG/ENGINE/WALK THRU | 12/10/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM05702
Permit Status: Final
Permit Description: ADDITION:BEDROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/09/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM05702
Permit Description: ADDITION:BEDROOM
Total Completed Inspections - 12
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/17/2003 | EXCAVATION/LAYOUT REBAR & ZON | JRIVA | Approved | IVRS - Inspection 0000* |
| 12/19/2003 | BUILDING PRE-SLAB | JRIVA | Approved | IVRS - Inspection 0000* |
| 12/31/2003 | FRAMING | JRIVA | Approved | IVRS - Inspection 0999* |
| 12/31/2003 | ROOF NAILING | JRIVA | Approved | IVRS - Inspection 0999* |
| 12/31/2003 | EXT METAL CLIPS/EXT SHEATHING | JRIVA | Approved | IVRS - Inspection 0999*/ 1) EXTERIOR SHEATHING NOT NAILED 2) PLAN CALLS FOR 2 X 8 RAFTERS AT 16" ON CENTER OR 2 X 10 AT 24" ON CENTER. 2 X 8 RAFTERS INSTALLED AT 24" ON CENTER NOT ALLOWED 3) DOOR OPENING REQUIRES DOUBLE 2 X 8 HEADERS. 2 X 6 INSTALLED 4) RAFTERS REQUIRE H2.5 CLIPS EACH END 5) BREAK THROUGH TO EXISTING HOUSE NOT COMPLETE |
| 01/16/2004 | MECHANICAL - INTERMEDIATE | JRIVA | Approved | |
| 01/16/2004 | ELECTRIC - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0000* |
| 01/16/2004 | SHEET ROCK NAILING | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/13/2004 | PERMIT FINALED | EDURAZO | Approved | |
| 02/17/2004 | MECHANICAL - FINAL | EDURAZO | Approved | IVRS - Inspection 0000* |
| 02/17/2004 | ELECTRIC - FINAL | EDURAZO | Approved | IVRS - Inspection 0000* |
| 02/17/2004 | BUILDING - FINAL | EDURAZO | Approved | IVRS - Inspection 0000* |