Permit: T03CM05679
Permit Details
Status:
Final
Type:
SINGLE FAMILY NEW
Address:
1351 S PLACITA BRISA SERENA
Address NEW:
1351 S PLACITA BRISA SERENA
Apply Date:
12/08/2003
Applicant:
N/A
Description:
SFR:TD#15-40-43
Contractors:
- T J BEDNAR & COMPANY
Permit Reviews
Permit Number - T03CM05679
Permit Status: Final
Permit Description: SFR:TD#15-40-43
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/08/2003 | RESIDENTIAL BLDG/ENGINE/WALK THRU | 12/16/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM05679
Permit Status: Final
Permit Description: SFR:TD#15-40-43
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/08/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM05679
Permit Description: SFR:TD#15-40-43
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/19/2004 | PLUMBING - SEWER HCS CONNECT | DBRITO | Approved | IVRS - Inspection 0000* |
| 03/19/2004 | PLUMBING - YARD WTR LINE/TEST | DBRITO | Approved | IVRS - Inspection 0000* |
| 03/19/2004 | PLUMBING - ROUGH, SOIL | DBRITO | Approved | IVRS - Inspection 0000* |
| 03/25/2004 | ELECTRIC - UFER | DBRITO | Approved | IVRS - Inspection 0000* |
| 03/25/2004 | BUILDING PRE-SLAB | DBRITO | Approved | IVRS - Inspection 0000* |
| 03/25/2004 | EXCAVATION/LAYOUT REBAR & ZON | DBRITO | Approved | IVRS - Inspection 0000*/ 1) FIRE BLOCKING AT LAUNDRY ROOM 2) ACCESS TO MASTER TUB (ELECTRIC) |
| 05/04/2004 | ELECTRIC - TEMPORARY SERVICE | FGREER | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 05/04/2004 | ELECTRIC - CABLE DROP | FGREER | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 05/04/2004 | ROOF NAILING | FGREER | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 05/05/2004 | TEP CLEARANCE - AM | JKOZUCH | Approved | |
| 05/17/2004 | EXT METAL CLIPS/EXT SHEATHING | JRIVA | Approved | IVRS - Inspection :* |
| 05/25/2004 | MECHANICAL - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection :* |
| 05/25/2004 | PLUMBING - GAS PRESSURE TEST | JRIVA | Approved | IVRS - Inspection :* |
| 05/25/2004 | ELECTRIC - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection :* |
| 05/28/2004 | PLUMBING - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
| 06/03/2004 | FRAMING | WNORTH | Approved | IVRS - Inspection :* |
| 06/21/2004 | SHEET ROCK NAILING | WNORTH | Approved | IVRS - Inspection :* |
| 06/22/2004 | U VALUE FOR WINDOW | WNORTH | Approved | IVRS - Inspection :* |
| 06/23/2004 | STUCCO MESH | WNORTH | Approved | IVRS - Inspection :* |
| 08/03/2004 | MECHANICAL - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 08/03/2004 | PLUMBING - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 08/04/2004 | ELECTRIC - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 08/04/2004 | BUILDING - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 02/22/2005 | PERMIT FINALED | LJACKSON | Approved |