Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
MULTI FAMILY NEW
Apply Date:
10/10/2003
Applicant:
METRO PERMIT EXPRESS, INC
Description:
APARTMENT:NEW
Architects:
  • WONG, CLIFFORD
Contractors:
  • FAIRFIELD DEVELOPMENT L P ,

Permit Reviews

Permit Number - T03CM04906
Permit Status: Final
Permit Description: APARTMENT:NEW
Start Date Submittal Complete Date Status  
02/04/2004 3RD PARTY REVIEW-COMMERCIAL ONLY 02/04/2004 COMPLETED Review Details
02/19/2004 3RD PARTY REVIEW-COMMERCIAL 04/23/2004 COMPLETED Review Details
04/23/2004 RESUBMITTAL 04/23/2004 COMPLETED Review Details
10/10/2003 PLANS OK TO SUBMIT - 3RD PARTY 12/03/2003 COMPLETED Review Details
12/04/2003 3RD PARTY REVIEW-COMMERCIAL 12/17/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM04906
Permit Status: Final
Permit Description: APARTMENT:NEW
Total Outstanding Activity Conditions - 1
Date Name
10/10/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T03CM04906
Permit Description: APARTMENT:NEW
Total Completed Inspections - 45
Date Description Inspector Results Comments
06/15/2004 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*/ PVC DWV UNDERGROUND OK. WTR TEST ONE RISER TO TEN FT. OK TO COVER.
08/05/2004 ELECTRIC - UNDERGROUND MCAPISTR Approved IVRS - Inspection :*/ 1) APPROVED TO CLOSE
08/05/2004 ELECTRIC - UFER MCAPISTR Approved IVRS - Inspection :*
08/06/2004 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection :*
08/06/2004 STEM WALL/RETAINING WALL AQUIROZ Approved IVRS - Inspection :*
08/06/2004 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection :*
08/10/2004 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*/SEE BLD. #2 WRITE UP
08/27/2004 ELECTRIC - TEMPORARY POLE DSANTACR Approved IVRS - Inspection :*
09/20/2004 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*/1)WILL NOT INSPECT UNTIL PRIVATE SEWER HAS BEEN APPROVED
09/24/2004 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*/1)CONNECTION AT BLDG. OK. NEED TO SEE CONNECTION AT METER
09/30/2004 EXT METAL CLIPS/EXT SHEATHING HLEYVA Approved IVRS - Inspection :*/ 1) OK NAILING AT SUB-FLOOR
12/22/2004 PLUMBING - ROOF DRAINS RMYERS Approved IVRS - Inspection :*/1)OK TO COVER ALL AREAS
12/22/2004 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
01/17/2005 ROOF NAILING HLEYVA Approved IVRS - Inspection :*
04/07/2005 FRAMING AQUIROZ Approved IVRS - Inspection :*
04/07/2005 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection :*
04/18/2005 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
05/11/2005 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
06/21/2005 TEP CLEARANCE - AM JKOZUCH Approved ECO
07/11/2005 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection :*
1) NO GAS ON THIS PERMIT
2) PLUMBING FINAL OK
3) OK FOR C OF O PENDING ANY OTHER INSPECTION
07/11/2005 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
07/11/2005 PLUMBING - PROGRESS RMYERS Approved IVRS - Inspection :*
07/11/2005 PLUMBING - GAS PRESS TEST FNL RMYERS Approved IVRS - Inspection :*
07/11/2005 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection :*
07/13/2005 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
07/14/2005 RIGHT OF WAY - FINAL MOTERO Approved PER EMAIL
07/14/2005 MECHANICAL - FINAL RMYERS Approved IVRS - Inspection :* 1) CONTRACTOR TO INSURE CONDENSATE /T & P RELIEF DRAINS ARE CUT BACK, AND 90 DEGREE ELLS ARE INSTALLED AT STUCCO REPAIR. 2) MECHANICAL FINAL OK OKFOR C OF O PENDING ANY OTHER INSEPCTION.
07/14/2005 MECHANICAL - PROGRESS RMYERS Approved IVRS - Inspection :*
07/14/2005 MECHANICAL - ABOVE CEILING RMYERS Approved IVRS - Inspection :*
07/22/2005 LANDSCAPE - FINAL ACONNOR Approved
07/25/2005 BUILDING - PROGRESS AQUIROZ Approved IVRS - Inspection :*
07/25/2005 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection :*
07/25/2005 BUILDING ABOVE CEILING AQUIROZ Approved IVRS - Inspection :*
07/26/2005 NPPO - FINAL ACONNOR Approved
07/26/2005 FIRE SPKLR - FINAL LLAKEY Approved
07/26/2005 FIRE - FINAL LLAKEY Approved
07/26/2005 ENGINEERING - FINAL MRUSSO Approved C OF O FOR ENGINEERING APPROVED. FAX ME A COPY OF THE ENGINEER CERTIFICATION STATEMENT FOR THE COMPLETED RET/DET BASINS - STATING THAT THE BASINS WERE BUILT PER APPROVED PLAN AND PERFORM IN ACCORDANCE WITH PRESCRIBED STANDARDS.

A FINAL GRADING INSPECTION #09190 FOR PERMIT #T03BU02470 WILL BE SCHEDULED AND ACCOMPLISHED THIS WEEK.
07/27/2005 ELECTRIC - ABOVE CEILING DSANTACR Approved
07/27/2005 OUTDOOR LIGHTING FINAL DSANTACR Approved
07/27/2005 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
07/28/2005 PERMIT FINALED AQUIROZ Approved
07/28/2005 FIRE SPKLR - OH PIPING & HYDRO LLAKEY Approved
07/28/2005 FIRE SPKLR - UG PIPING FLUSH LLAKEY Approved
07/28/2005 FIRE SPKLR - UG, PIPING, HYDRO LLAKEY Approved
07/28/2005 BUILDING - FINAL AQUIROZ Approved