Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address NEW:
441 W HAMMERHEAD WY
Apply Date:
10/01/2003
Applicant:
K B HOME OF TUCSON ****''T''
Description:
SFR:TD#15-44-87
Contractors:
  • K B HOME OF TUCSON ****''T''

Permit Reviews

Permit Number - T03CM04730
Permit Status: C of o
Permit Description: SFR:TD#15-44-87
Start Date Submittal Complete Date Status  
10/01/2003 RESIDENTIAL BLDG/ENGINE/WALK THRU 10/01/2003 COMPLETED Review Details
10/03/2003 RESIDENTIAL BLDG/ENGINE/WALK THRU 10/06/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM04730
Permit Status: C of o
Permit Description: SFR:TD#15-44-87
Total Outstanding Activity Conditions - 1
Date Name
10/01/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T03CM04730
Permit Description: SFR:TD#15-44-87
Total Completed Inspections - 22
Date Description Inspector Results Comments
10/14/2003 PLUMBING - SEWER HCS CONNECT FGREER Approved IVRS - Inspection 0000*
10/14/2003 PLUMBING - YARD WTR LINE/TEST FGREER Approved IVRS - Inspection 0000*
10/14/2003 PLUMBING - ROUGH, SOIL FGREER Approved IVRS - Inspection 0000*
10/27/2003 ELECTRIC - UFER ROHAVER Approved IVRS - Inspection 0999* NOT INSTALLED
10/27/2003 BUILDING PRE-SLAB ROHAVER Approved IVRS - Inspection 0000*
10/27/2003 EXCAVATION/LAYOUT REBAR & ZON ROHAVER Approved IVRS - Inspection 0000*
11/20/2003 ROOF NAILING JRIVA Approved IVRS - Inspection 0000*
11/20/2003 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved IVRS - Inspection 0000*
12/31/2003 MECHANICAL - INTERMEDIATE JRIVA Approved IVRS - Inspection 0950*
12/31/2003 PLUMBING - INTERMEDIATE JRIVA Approved IVRS - Inspection 0950*
12/31/2003 ELECTRIC - INTERMEDIATE JRIVA Approved IVRS - Inspection 0950*
12/31/2003 U VALUE FOR WINDOW JRIVA Approved IVRS - Inspection 0000*
12/31/2003 STUCCO MESH JRIVA Approved IVRS - Inspection 0000*
12/31/2003 FRAMING JRIVA Approved IVRS - Inspection 0950*/ 1) RED HEAD ANCHOR BOLTS LOOSE 2) SHEAR WALL P-2 REQUIRES 4" EDGE NAILING 3) HOLDOWNS NOT INSTALLED 4) NO DWV WATER TEST 5) NAIL PROTECT PLUMBING 6) DRAIN PIPES REQUIRE 1/4" PER FOOT PITCH 7) STOPPED INSPECTION TO MANY ITEMS
01/14/2004 SHEET ROCK NAILING ROHAVER Approved IVRS - Inspection 0000*
01/23/2004 ELECTRIC - TEMPORARY SERVICE ROHAVER Approved IVRS - Inspection 0000*SENT TO TEP ON 01/26/04AM
01/23/2004 ELECTRIC - CABLE DROP ROHAVER Approved IVRS - Inspection 0000*SENT TO TEP ON 01/26/04AM
03/25/2004 PERMIT FINALED JRIVA Approved
03/25/2004 MECHANICAL - FINAL JRIVA Approved IVRS - Inspection 0000*
03/25/2004 PLUMBING - FINAL JRIVA Approved IVRS - Inspection 0000*
03/25/2004 ELECTRIC - FINAL JRIVA Approved IVRS - Inspection 0000*
03/25/2004 BUILDING - FINAL JRIVA Approved IVRS - Inspection 0000*