Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address NEW:
6196 E BRAMBLE ST
Apply Date:
09/30/2003
Applicant:
K B HOME OF TUCSON ****''T''
Description:
SFR:TD#15-44-89
Contractors:
  • K B HOME OF TUCSON ****''T''

Permit Reviews

Permit Number - T03CM04712
Permit Status: C of o
Permit Description: SFR:TD#15-44-89
Start Date Submittal Complete Date Status  
09/30/2003 RESIDENTIAL BLDG/ENGINE/WALK THRU 10/01/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM04712
Permit Status: C of o
Permit Description: SFR:TD#15-44-89
Total Outstanding Activity Conditions - 1
Date Name
09/30/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T03CM04712
Permit Description: SFR:TD#15-44-89
Total Completed Inspections - 24
Date Description Inspector Results Comments
10/29/2003 PLUMBING - SEWER HCS CONNECT HPEDROZA Approved IVRS - Inspection 0000*
10/29/2003 PLUMBING - YARD WTR LINE/TEST HPEDROZA Approved IVRS - Inspection 0000*
10/29/2003 PLUMBING - ROUGH, SOIL HPEDROZA Approved IVRS - Inspection 0000*
11/10/2003 ELECTRIC - UFER HPEDROZA Approved IVRS - Inspection 0000*
11/10/2003 BUILDING PRE-SLAB HPEDROZA Approved IVRS - Inspection 0000*
11/10/2003 EXCAVATION/LAYOUT REBAR & ZON HPEDROZA Approved IVRS - Inspection 0000*
12/04/2003 EXT METAL CLIPS/EXT SHEATHING HPEDROZA Approved IVRS - Inspection 0000*
12/10/2003 ROOF NAILING DQUINN Approved IVRS - Inspection 0000*
12/31/2003 MECHANICAL - INTERMEDIATE HPEDROZA Approved IVRS - Inspection 0999*
12/31/2003 PLUMBING - GAS PRESSURE TEST HPEDROZA Approved IVRS - Inspection 0000*
12/31/2003 PLUMBING - INTERMEDIATE HPEDROZA Approved IVRS - Inspection 0000*
12/31/2003 ELECTRIC - INTERMEDIATE HPEDROZA Approved IVRS - Inspection 0999*
12/31/2003 FRAMING HPEDROZA Approved IVRS - Inspection 0999*/ 1) ENTRY WAY LEDGERS NOT NAILED 2) THA 48 AND LUSZ6 MISSING NAILS ABOVE STAIRS 3) EXHAUST FAN NOT HOOKED UP AT POWDER ROOM 4) CHASE MISSING 2ND FLOOR FOR WATER HEATER FLU AND FIRE BLOCK 5) CONDENSATE LINES NOT HOOKED UP 6) HD'S MISSING AT GARAGE WALL 7) UPSTAIRS HALL LIGHT BOX NOT SECURED 8) EXHAUST FAN UPSTAIRS BATH ROMEX NOT HOOKED UP, LAUNDRY ROOM AND MASTER BATH
01/14/2004 STUCCO MESH HPEDROZA Approved IVRS - Inspection 0000*
02/04/2004 SHEET ROCK NAILING HPEDROZA Approved IVRS - Inspection 0000*
02/13/2004 ELECTRIC - TEMPORARY SERVICE HPEDROZA Approved SENT TO TEP 02/17/04AM
02/13/2004 ELECTRIC - CABLE DROP HPEDROZA Approved SENT TO TEP 02/17/04AM
03/17/2004 MECHANICAL - FINAL HPEDROZA Approved IVRS - Inspection 0000*
03/17/2004 ELECTRIC - FINAL HPEDROZA Approved IVRS - Inspection 0000*
03/18/2004 PERMIT FINALED HPEDROZA Approved
03/18/2004 PLUMBING - FINAL HPEDROZA Approved IVRS - Inspection 0000*
03/18/2004 BUILDING - FINAL HPEDROZA Approved IVRS - Inspection 0000*
03/18/2004 U VALUE FOR WINDOW HPEDROZA Approved IVRS - Inspection 0000*
03/19/2004 TEP CLEARANCE - AM HPEDROZA Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CERT OF OCC VIEW