Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address NEW:
1670 E RIVER RD #100
Apply Date:
09/10/2003
Applicant:
METRO PERMIT EXPRESS, INC
Description:
TI:OFFICE
Architects:
  • SAYLER BROWN ARCHITECTS/PLANNER
Contractors:
  • TRIUMPH BUILDERS SOUTHWEST LLC *C*

Permit Reviews

Permit Number - T03CM04424
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date Submittal Complete Date Status  
09/10/2003 COMMERCIAL TI 10/07/2003 COMPLETED Review Details
10/09/2003 REVISION 10/15/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM04424
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date Name
09/10/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T03CM04424
Permit Description: TI:OFFICE
Total Completed Inspections - 21
Date Description Inspector Results Comments
10/10/2003 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection 0000*/1) ABS DWV BELOW GRADE OK. 2) ONE RISER TO TEN FEET OK. 3) OK TO COVER. 4) PLEASE HAVE YOUR SUITE NUMBER ADDED TO PERMIT AND THEN POST IT.
10/10/2003 FRAMING LHANLY Approved IVRS - Inspection 0000*
10/20/2003 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection 0000* 1. SUBJECT TO APPROVAL BY ENGINEER OF RECORD, OF THE USE OF M.C. CABLE IN LIEU OF THE SPECIFIED EMT CONDUIT IN WALLS, CEILING, ETC. 2. HAVE ENGINEER ISSUE A LETTER FOR THIS APPROVAL.
RECIEVED LETTER FROM ENG ON OK MC USE.
10/21/2003 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection 0000*
11/07/2003 PLUMBING - FINAL RMYERS Approved IVRS - Inspection 0000*
11/07/2003 PLUMBING - PROGRESS RMYERS Approved IVRS - Inspection 0000*/ 1) P CORRECTIONS MADE OK. PLBG FINAL OK. OK FOR C OF O PENDING ANY OTHER INSPECTION.
11/07/2003 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection 0000*
11/07/2003 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection 0000*
11/07/2003 ELECTRIC - FINAL MCAPISTR Approved IVRS - Inspection 0000*
11/07/2003 BUILDING ABOVE CEILING AMATHIES Approved IVRS - Inspection 0000*
11/10/2003 SIGN - FINAL JYBARRA Approved NO SIGNS AT THIS TIME
11/10/2003 FIRE - FINAL JEGAN Approved IVRS - Inspection 0000*/ 1) OK C OF O
11/10/2003 FIRE SPKLR - FINAL JEGAN Approved IVRS - Inspection 0000*
11/12/2003 RIGHT OF WAY - FINAL MOTERO Approved
11/12/2003 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*
11/12/2003 MECHANICAL - PROGRESS CWILLIAM Approved
11/12/2003 MECHANICAL - ABOVE CEILING CWILLIAM Approved
11/12/2003 MECHANICAL - INTERMEDIATE CWILLIAM Approved
11/12/2003 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection 0000*
11/13/2003 PERMIT FINALED JBRUCKME Approved
11/13/2003 ENGINEERING - FINAL JBRUCKME Approved