Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T03CM04380
Permit Details
Apply Date:
09/08/2003
Applicant:
SBBA- FRANK MENDOZA
Description:
TI:RETAIL
Architects:
- SHAW, RALPH R
Contractors:
- SUMMIT BUILDERS ,
Permit Reviews
Permit Number - T03CM04380
Permit Status: C of o
Permit Description: TI:RETAIL
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/14/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 01/20/2004 | COMPLETED |
01/21/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 01/28/2004 | COMPLETED |
02/10/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 02/23/2004 | COMPLETED |
02/26/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 03/08/2004 | COMPLETED |
09/08/2003 | PLANS OK TO SUBMIT - 3RD PARTY | 09/08/2003 | COMPLETED |
09/09/2003 | 3RD PARTY REVIEW-COMMERCIAL TI | 09/15/2003 | COMPLETED |
09/26/2003 | 3RD PARTY REVIEW-COMMERCIAL | 12/05/2003 | COMPLETED |
10/29/2003 | SITE | 12/05/2003 | COMPLETED |
12/08/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 12/19/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM04380
Permit Status: C of o
Permit Description: TI:RETAIL
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
09/08/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM04380
Permit Description: TI:RETAIL
Total Completed Inspections - 35
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/30/2003 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0999*/ MUST SHADE ENTIRE TRENCH TO TOP OF PIPE. |
12/30/2003 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection 0000*/ OK CONDUIT STUB UPS AT ELECTRIC ROOM #1. |
12/31/2003 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | IVRS - Inspection 0000* |
12/31/2003 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000* C-A&B PIERS GARDEN FOOTINGS |
02/11/2004 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
02/27/2004 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000*/ 1) OK ABOVE CEILING OFFICE, RESTROOM AREAS, PHONE ROOM 2) EXCEPT EAST END OF CARD STORAGE, WEST END OF CLASS ROOM 2) OK SOFFITS IN STORE FRONT EXCEPT MAIN EXIT, EAST OUTSIDE BY MAIN ENTRANCE |
03/02/2004 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
03/02/2004 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection 0000* |
03/02/2004 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) OVERHEAD WATER DISTRIBUTION IS OK. |
03/02/2004 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000* |
03/02/2004 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
03/02/2004 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection 0000* |
03/02/2004 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
03/02/2004 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
03/05/2004 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection 0000* |
03/11/2004 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000* |
03/11/2004 | ELECTRIC - SERVICE UPGRADE | DSANTACR | Approved | IVRS - Inspection 0000* |
03/11/2004 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection 0000* |
03/12/2004 | ENGINEERING - FINAL | DROBERTS | Approved | |
03/12/2004 | PLUMBING - GAS RECONNECT | TRINIVJR | Approved | IVRS - Inspection 0000* |
03/12/2004 | PLUMBING - GAS PRESS TEST FNL | TRINIVJR | Approved | IVRS - Inspection 0000* |
03/16/2004 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000*/ 1) PLBG FINAL IS OK. 2) OK FOR C OF O. |
03/16/2004 | PLUMBING - ROOF DRAINS | TRINIVJR | Approved | IVRS - Inspection 0000* |
03/25/2004 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
03/26/2004 | FIRE SPKLR - FINAL | LTHOMAS | Approved | 1) OK C OF O |
03/30/2004 | FIRE - FINAL | LTHOMAS | Approved | |
04/01/2004 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
04/01/2004 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection 0000* |
04/14/2004 | OUTDOOR LIGHTING FINAL | DSANTACR | Approved | IVRS - Inspection 0000* |
05/06/2004 | NPPO - FINAL | ACONNOR | Approved | |
05/06/2004 | LANDSCAPE - FINAL | ACONNOR | Approved | |
05/06/2004 | ELECTRIC - FINAL | DSANTACR | Approved | OK C OF O, |
05/06/2004 | BUILDING - FINAL | AMATHIES | Approved | |
05/06/2004 | STEM WALL/RETAINING WALL | AMATHIES | Approved | |
10/09/2008 | SIGN - FINAL | LHANLY | Approved |