Permit: T03CM03891
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
2443 N ORCHARD AV
Address NEW:
2443 N ORCHARD AV
Apply Date:
08/06/2003
Applicant:
MIKE AAKER/GARY HICKEY
Description:
ADDITION:BATHROOM/REPLACE:WATER HEATER
Permit Reviews
Permit Number - T03CM03891
Permit Status: Expired
Permit Description: ADDITION:BATHROOM/REPLACE:WATER HEATER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/06/2003 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 08/15/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM03891
Permit Status: Expired
Permit Description: ADDITION:BATHROOM/REPLACE:WATER HEATER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/06/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T03CM03891
Permite Description: ADDITION:BATHROOM/REPLACE:WATER HEATER
Total Outstanding Inspections - 11
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/21/2003 | FRAMING | N/A | Denied | IVRS - Inspection 0999*/ 1) WATER HEATER MUST HAVE CONTINOUS RISE 2) CLEANOUT REQUIRES PROPER CAP 3) EXPOSE CONNECTION TO EXISTING SEWER 4) VENT AND DRAIN IN EXISTING LAUNDRY MUST BE REPLACED WITH MATERIALS APPROVED FOR USE INSIDE HOME 5) EXPOSE PLUMBING IN WALL BETWEEN BATH AND CLOSET 6) EXPOSE ELECTRICAL IN WALL BETWEEN BATH AND CLOSET 7) ALL BEDROOMS MUST HAVE SMOKE DETECTORS 8) SCOPE OR EXPOSE RGH PLUMBING (IF SCOPED, PROVIDE LETTER FROM PLB CONTRACTOR TO VERIFY) 9) IF MECHANICAL WAS CHANGED AT TIME OF BATH ADDITION, COOLER OUTLET AND DISCONNECT MUST MEET CURRENT CODE |
| 08/21/2003 | SHEET ROCK NAILING | N/A | Denied | IVRS - Inspection 0999* |
| 08/21/2003 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection 0950* |
| 08/21/2003 | ELECTRIC - INTERMEDIATE | N/A | Denied | IVRS - Inspection 0999* |
| 08/21/2003 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection 0950* |
| 08/21/2003 | PLUMBING - ROUGH, SOIL | N/A | Denied | IVRS - Inspection 0999* |
| 08/21/2003 | PLUMBING - INTERMEDIATE | N/A | Denied | IVRS - Inspection 0999* |
| 08/21/2003 | PLUMBING - SEWER HCS CONNECT | N/A | Denied | IVRS - Inspection 0999* |
| 08/21/2003 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection 0950* |
| 08/21/2003 | MECHANICAL - INTERMEDIATE | N/A | Denied | IVRS - Inspection 0999* |
| 08/21/2003 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection 0950* |