Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T03CM03821
Permit Details
Apply Date:
08/01/2003
Applicant:
SHELLEY ABOUD
Description:
ADDITION:GUEST HOUSE
Permit Reviews
Permit Number - T03CM03821
Permit Status: Final
Permit Description: ADDITION:GUEST HOUSE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/01/2003 | PLANS OK TO SUBMIT - RES | 08/01/2003 | COMPLETED |
| 08/04/2003 | RESIDENTIAL BLDG/WWM | 09/03/2003 | COMPLETED |
| 09/10/2003 | RESUBMITTAL | 10/09/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM03821
Permit Status: Final
Permit Description: ADDITION:GUEST HOUSE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/01/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM03821
Permit Description: ADDITION:GUEST HOUSE
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/17/2003 | ELECTRIC - UFER | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 10/17/2003 | EXCAVATION/LAYOUT REBAR & ZON | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 10/24/2003 | PLUMBING - YARD WTR LINE/TEST | MTESTER | Approved | |
| 10/24/2003 | PLUMBING - ROUGH, SOIL | MTESTER | Approved | IVRS - Inspection 0000* |
| 10/24/2003 | STEM WALL/RETAINING WALL | MTESTER | Approved | IVRS - Inspection 0000*/ 1) OK TO BACKFILL AND PREPARE FOR PRE-SLAB |
| 10/28/2003 | BUILDING PRE-SLAB | FGREER | Approved | IVRS - Inspection 0000* |
| 11/18/2003 | ROOF NAILING | JRIVA | Approved | IVRS - Inspection 0000* |
| 11/18/2003 | EXT METAL CLIPS/EXT SHEATHING | JRIVA | Approved | IVRS - Inspection 0000* |
| 12/12/2003 | MECHANICAL - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 12/12/2003 | PLUMBING - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 12/12/2003 | ELECTRIC - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 12/12/2003 | FRAMING | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 12/17/2003 | SHEET ROCK NAILING | DQUINN | Approved | IVRS - Inspection 0000* |
| 03/11/2004 | PLUMBING - SEWER HCS CONNECT | JRIVA | Approved | IVRS - Inspection 0000* |
| 03/24/2004 | ELECTRIC - TEMPORARY SERVICE | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 03/24/2004 | ELECTRIC - CABLE DROP | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 03/25/2004 | TEP CLEARANCE - AM | BSTEVENS | Approved | |
| 06/03/2004 | PERMIT FINALED | BSTEVENS | Approved | |
| 06/03/2004 | MECHANICAL - FINAL | BSTEVENS | Approved | IVRS - Inspection :* |
| 06/03/2004 | PLUMBING - FINAL | BSTEVENS | Approved | IVRS - Inspection :* |
| 06/03/2004 | ELECTRIC - FINAL | BSTEVENS | Approved | IVRS - Inspection :* |
| 06/03/2004 | BUILDING - FINAL | BSTEVENS | Approved | IVRS - Inspection :* |
| 06/03/2004 | U VALUE FOR WINDOW | BSTEVENS | Approved | |
| 06/03/2004 | STUCCO MESH | BSTEVENS | Approved |