Permit: T03CM03793
Permit Details
Apply Date:
07/31/2003
Applicant:
ED CURRAN
Description:
NEW:DUPLEX
Contractors:
- CURRAN BUILDING COMPANY L L C
Permit Reviews
Permit Number - T03CM03793
Permit Status: Final
Permit Description: NEW:DUPLEX
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/31/2003 | PLANS OK TO SUBMIT - RES | 07/31/2003 | COMPLETED |
| 07/31/2003 | RESIDENTIAL BLDG/WWM | 08/26/2003 | COMPLETED |
| 09/10/2003 | RESUBMITTAL | 01/09/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM03793
Permit Status: Final
Permit Description: NEW:DUPLEX
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/31/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM03793
Permit Description: NEW:DUPLEX
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/04/2004 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK. 2) BLDG SEWER IS STUBBED at p.l. only. 3) ok to backfill trench. 4) APPROVED PLAN CALLS FOR 2" SEPERATE RISER FOR A.W. IT APPEARS THAT YOU WANT TO WET VENT THIS FIXTURE. PLEASE RED LINE PLAN TO INDICATE THIS. 5) YARD WATER LINES CAN NOT BE BENDED OR HAVE STRESS ON PIPE. MUST USE SWING JOINTS TO MAKE THE RADIUS. DO NOT COVER! |
| 03/03/2004 | ROOF NAILING | AMATHIES | Approved | |
| 03/03/2004 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | |
| 03/23/2004 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 03/23/2004 | ELECTRIC - TEMPORARY SERVICE | DSANTACR | Approved | IVRS - Inspection 0000* |
| 03/23/2004 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection 0000* |
| 03/23/2004 | U VALUE FOR WINDOW | AMATHIES | Approved | IVRS - Inspection 0000* |
| 03/23/2004 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
| 03/23/2004 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000* |
| 03/24/2004 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection 0000* |
| 03/24/2004 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) OVERHEAD WTR DISTRIBUTION IS OK. 3) SOIL WTR TEST IS OK. 4) OK FOR DRYWALL. |
| 03/24/2004 | TEP CLEARANCE - AM | SREEVES | Approved | |
| 03/24/2004 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000* |
| 03/25/2004 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 04/05/2004 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection 0000*/ 1) YARD WTR LINE FROM METER TO BLDG SERVICE IS OK. 2) OK TO BACKFILL TRENCH. |
| 04/12/2004 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection :* |
| 04/20/2004 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 04/28/2004 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :*/ 1) SEWER TAP AND SADDLE OK 2) SEWER TO PROPERTY LINE OK 3) WATER TEST OK 4) OK TO COVER |
| 05/27/2004 | PLUMBING - GAS PRESS TEST FNL | TRINIVJR | Approved | IVRS - Inspection :* |
| 05/28/2004 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 06/01/2004 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
| 06/02/2004 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :*/ 1) OK TO CLEAR UNIT 1 AND 2 ECO |
| 06/02/2004 | ELECTRIC - CABLE DROP | DSANTACR | Approved | IVRS - Inspection :* |
| 06/02/2004 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* |
| 06/03/2004 | PERMIT FINALED | AMATHIES | Approved |