Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
DUPLEX NEW
Address NEW:
501 S FREMONT AV #01
Apply Date:
07/31/2003
Applicant:
ED CURRAN
Description:
NEW:DUPLEX
Contractors:
  • CURRAN BUILDING COMPANY L L C

Permit Reviews

Permit Number - T03CM03793
Permit Status: Final
Permit Description: NEW:DUPLEX
Start Date Submittal Complete Date Status  
07/31/2003 PLANS OK TO SUBMIT - RES 07/31/2003 COMPLETED Review Details
07/31/2003 RESIDENTIAL BLDG/WWM 08/26/2003 COMPLETED Review Details
09/10/2003 RESUBMITTAL 01/09/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM03793
Permit Status: Final
Permit Description: NEW:DUPLEX
Total Outstanding Activity Conditions - 1
Date Name
07/31/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T03CM03793
Permit Description: NEW:DUPLEX
Total Completed Inspections - 25
Date Description Inspector Results Comments
02/04/2004 PLUMBING - ROUGH, SOIL TRINIVJR Approved IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK. 2) BLDG SEWER IS STUBBED at p.l. only. 3) ok to backfill trench. 4) APPROVED PLAN CALLS FOR 2" SEPERATE RISER FOR A.W. IT APPEARS THAT YOU WANT TO WET VENT THIS FIXTURE. PLEASE RED LINE PLAN TO INDICATE THIS. 5) YARD WATER LINES CAN NOT BE BENDED OR HAVE STRESS ON PIPE. MUST USE SWING JOINTS TO MAKE THE RADIUS. DO NOT COVER!
03/03/2004 ROOF NAILING AMATHIES Approved
03/03/2004 EXT METAL CLIPS/EXT SHEATHING AMATHIES Approved
03/23/2004 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
03/23/2004 ELECTRIC - TEMPORARY SERVICE DSANTACR Approved IVRS - Inspection 0000*
03/23/2004 ELECTRIC - UFER DSANTACR Approved IVRS - Inspection 0000*
03/23/2004 U VALUE FOR WINDOW AMATHIES Approved IVRS - Inspection 0000*
03/23/2004 BUILDING PRE-SLAB AMATHIES Approved IVRS - Inspection 0000*
03/23/2004 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved IVRS - Inspection 0000*
03/24/2004 PLUMBING - GAS PRESSURE TEST TRINIVJR Approved IVRS - Inspection 0000*
03/24/2004 PLUMBING - INTERMEDIATE TRINIVJR Approved IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) OVERHEAD WTR DISTRIBUTION IS OK. 3) SOIL WTR TEST IS OK. 4) OK FOR DRYWALL.
03/24/2004 TEP CLEARANCE - AM SREEVES Approved
03/24/2004 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection 0000*
03/25/2004 FRAMING AMATHIES Approved IVRS - Inspection 0000*
04/05/2004 PLUMBING - YARD WTR LINE/TEST TRINIVJR Approved IVRS - Inspection 0000*/ 1) YARD WTR LINE FROM METER TO BLDG SERVICE IS OK. 2) OK TO BACKFILL TRENCH.
04/12/2004 STUCCO MESH AMATHIES Approved IVRS - Inspection :*
04/20/2004 SHEET ROCK NAILING AMATHIES Approved IVRS - Inspection 0000*
04/28/2004 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*/ 1) SEWER TAP AND SADDLE OK 2) SEWER TO PROPERTY LINE OK 3) WATER TEST OK 4) OK TO COVER
05/27/2004 PLUMBING - GAS PRESS TEST FNL TRINIVJR Approved IVRS - Inspection :*
05/28/2004 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
06/01/2004 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
06/02/2004 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*/ 1) OK TO CLEAR UNIT 1 AND 2 ECO
06/02/2004 ELECTRIC - CABLE DROP DSANTACR Approved IVRS - Inspection :*
06/02/2004 BUILDING - FINAL AMATHIES Approved IVRS - Inspection :*
06/03/2004 PERMIT FINALED AMATHIES Approved