Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
06/30/2003
Applicant:
COLLIER DENNIS NED & LORALEI L J
Description:
ADDITION:GUEST HOUSE/GARAGE

Outstanding Activity Conditions

Permit Number - T03CM03175
Permit Status: C of o
Permit Description: ADDITION:GUEST HOUSE/GARAGE
Total Outstanding Activity Conditions - 1
Date Name
06/30/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T03CM03175
Permit Description: ADDITION:GUEST HOUSE/GARAGE
Total Completed Inspections - 22
Date Description Inspector Results Comments
10/07/2003 ELECTRIC - UFER HCAMPBEL Approved IVRS - Inspection 0000*
10/07/2003 EXCAVATION/LAYOUT REBAR & ZON HCAMPBEL Approved IVRS - Inspection 0000*
10/14/2003 STEM WALL/RETAINING WALL HCAMPBEL Approved IVRS - Inspection 0000*
10/21/2003 PLUMBING - SEWER HCS CONNECT HCAMPBEL Approved
10/21/2003 PLUMBING - YARD WTR LINE/TEST HCAMPBEL Approved
10/21/2003 PLUMBING - ROUGH, SOIL HCAMPBEL Approved IVRS - Inspection 0000*
10/23/2003 BUILDING PRE-SLAB EDURAZO Approved IVRS - Inspection 0000*
11/04/2003 REINFORCED MASONRY PRE-GROUT HCAMPBEL Approved IVRS - Inspection 0000*
12/10/2003 ROOF NAILING JRIVA Approved IVRS - Inspection 0000*/ 1) ROOF NAIL OK BUT TWO TRUSS BRACE (RAT RUNS) NOT IN-SEE TRUSS CALC'S. DO NOT LOAD ROOF UNTIL BRACES INSTALLED 2) X BRACE 3 TRUSSES AT MID POINT AT EACH END OF ROOF AND MID WAY BETWEEN ENDS (3 CROSS BRACES TOTAL)
12/23/2003 MECHANICAL - INTERMEDIATE HCAMPBEL Approved IVRS - Inspection 0999*/ 1) REVISE PLAN TO SHOW ACTUAL INSTALLATION OR INSTALL AS SHOWN.
12/23/2003 PLUMBING - INTERMEDIATE HCAMPBEL Approved IVRS - Inspection 0999*/ 1) INSTALL 3/4" WATER TO BATHS [THROUGHOUT] PER DETAIL OR REVISE PLAN. 2) SECURE PVC IN KITCHEN WALL. 3) NAIL PLATE WASTE IN HALL BATH ON BEDROOM SIDE. 4) INSTALL WTR CLOSET RINGS. 5) FLAT TRAP ARM AT MASTER BATH. 6) NAIL PLATE TPR IN GARAGE.
12/23/2003 ELECTRIC - INTERMEDIATE HCAMPBEL Approved IVRS - Inspection 0999*/ 1) REPAIR SHEATHING AT CONDUCTOR UNDER FRONT WINDOW. 2) NAIL PLATE WITHIN 1ΒΌ" OF STUD/PLATE EDGES.
12/23/2003 FRAMING HCAMPBEL Approved IVRS - Inspection 0999*/ 1) INSTALL LATERAL BRACING AT GABLE TRUSSES. 2) SAFETY GLAZE REQUIRED AT ENTRY. 3) SOUTHEAST BEDROOM DOES NOT MEET EGRESS REQUIREMENTS.
12/30/2003 ELECTRIC - SERVICE UPGRADE HCAMPBEL Approved IVRS - Inspection 0000*SENT TO TEP ON 12/31/03AM
01/12/2004 SHEET ROCK NAILING SLONG Approved 1) USE NON-SAG RESISTANT GYP BOARD OK'D BY S. LONG IN THIS ONE CASE
03/23/2004 PERMIT FINALED HCAMPBEL Approved
03/23/2004 MECHANICAL - FINAL HCAMPBEL Approved IVRS - Inspection 0000*
03/23/2004 PLUMBING - FINAL HCAMPBEL Approved IVRS - Inspection 0000*
03/23/2004 ELECTRIC - FINAL HCAMPBEL Approved IVRS - Inspection 0000*
03/23/2004 BUILDING - FINAL HCAMPBEL Approved IVRS - Inspection 0000*
03/23/2004 U VALUE FOR WINDOW HCAMPBEL Approved
03/24/2004 TEP CLEARANCE - AM SREEVES Approved