Permit: T03CM03175
Permit Details
Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
1600 N CAMINO MIRAFLORES
Address NEW:
1600 N CAMINO MIRAFLORES
Apply Date:
06/30/2003
Applicant:
COLLIER DENNIS NED & LORALEI L J
Description:
ADDITION:GUEST HOUSE/GARAGE
Outstanding Activity Conditions
Permit Number - T03CM03175
Permit Status: C of o
Permit Description: ADDITION:GUEST HOUSE/GARAGE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/30/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM03175
Permit Description: ADDITION:GUEST HOUSE/GARAGE
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/07/2003 | ELECTRIC - UFER | HCAMPBEL | Approved | IVRS - Inspection 0000* |
| 10/07/2003 | EXCAVATION/LAYOUT REBAR & ZON | HCAMPBEL | Approved | IVRS - Inspection 0000* |
| 10/14/2003 | STEM WALL/RETAINING WALL | HCAMPBEL | Approved | IVRS - Inspection 0000* |
| 10/21/2003 | PLUMBING - SEWER HCS CONNECT | HCAMPBEL | Approved | |
| 10/21/2003 | PLUMBING - YARD WTR LINE/TEST | HCAMPBEL | Approved | |
| 10/21/2003 | PLUMBING - ROUGH, SOIL | HCAMPBEL | Approved | IVRS - Inspection 0000* |
| 10/23/2003 | BUILDING PRE-SLAB | EDURAZO | Approved | IVRS - Inspection 0000* |
| 11/04/2003 | REINFORCED MASONRY PRE-GROUT | HCAMPBEL | Approved | IVRS - Inspection 0000* |
| 12/10/2003 | ROOF NAILING | JRIVA | Approved | IVRS - Inspection 0000*/ 1) ROOF NAIL OK BUT TWO TRUSS BRACE (RAT RUNS) NOT IN-SEE TRUSS CALC'S. DO NOT LOAD ROOF UNTIL BRACES INSTALLED 2) X BRACE 3 TRUSSES AT MID POINT AT EACH END OF ROOF AND MID WAY BETWEEN ENDS (3 CROSS BRACES TOTAL) |
| 12/23/2003 | MECHANICAL - INTERMEDIATE | HCAMPBEL | Approved | IVRS - Inspection 0999*/ 1) REVISE PLAN TO SHOW ACTUAL INSTALLATION OR INSTALL AS SHOWN. |
| 12/23/2003 | PLUMBING - INTERMEDIATE | HCAMPBEL | Approved | IVRS - Inspection 0999*/ 1) INSTALL 3/4" WATER TO BATHS [THROUGHOUT] PER DETAIL OR REVISE PLAN. 2) SECURE PVC IN KITCHEN WALL. 3) NAIL PLATE WASTE IN HALL BATH ON BEDROOM SIDE. 4) INSTALL WTR CLOSET RINGS. 5) FLAT TRAP ARM AT MASTER BATH. 6) NAIL PLATE TPR IN GARAGE. |
| 12/23/2003 | ELECTRIC - INTERMEDIATE | HCAMPBEL | Approved | IVRS - Inspection 0999*/ 1) REPAIR SHEATHING AT CONDUCTOR UNDER FRONT WINDOW. 2) NAIL PLATE WITHIN 1ΒΌ" OF STUD/PLATE EDGES. |
| 12/23/2003 | FRAMING | HCAMPBEL | Approved | IVRS - Inspection 0999*/ 1) INSTALL LATERAL BRACING AT GABLE TRUSSES. 2) SAFETY GLAZE REQUIRED AT ENTRY. 3) SOUTHEAST BEDROOM DOES NOT MEET EGRESS REQUIREMENTS. |
| 12/30/2003 | ELECTRIC - SERVICE UPGRADE | HCAMPBEL | Approved | IVRS - Inspection 0000*SENT TO TEP ON 12/31/03AM |
| 01/12/2004 | SHEET ROCK NAILING | SLONG | Approved | 1) USE NON-SAG RESISTANT GYP BOARD OK'D BY S. LONG IN THIS ONE CASE |
| 03/23/2004 | PERMIT FINALED | HCAMPBEL | Approved | |
| 03/23/2004 | MECHANICAL - FINAL | HCAMPBEL | Approved | IVRS - Inspection 0000* |
| 03/23/2004 | PLUMBING - FINAL | HCAMPBEL | Approved | IVRS - Inspection 0000* |
| 03/23/2004 | ELECTRIC - FINAL | HCAMPBEL | Approved | IVRS - Inspection 0000* |
| 03/23/2004 | BUILDING - FINAL | HCAMPBEL | Approved | IVRS - Inspection 0000* |
| 03/23/2004 | U VALUE FOR WINDOW | HCAMPBEL | Approved | |
| 03/24/2004 | TEP CLEARANCE - AM | SREEVES | Approved |