Permit: T03CM02737
Permit Details
Apply Date:
06/04/2003
Applicant:
METRO PERMIT EXPRESS, INC
Description:
NEW:CONDOS
Architects:
- BOLDUC, VICTOR
Contractors:
- RIVERSIDE BUILDERS INC
Permit Reviews
Permit Number - T03CM02737
Permit Status: Final
Permit Description: NEW:CONDOS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/11/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 03/23/2004 | COMPLETED |
| 06/03/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 06/08/2004 | COMPLETED |
| 06/04/2003 | PLANS OK TO SUBMIT - 3RD PARTY | 06/05/2003 | COMPLETED |
| 06/04/2003 | SITE | 12/02/2003 | COMPLETED |
| 06/06/2003 | 3RD PARTY REVIEW-COMMERCIAL | 06/12/2003 | COMPLETED |
| 07/25/2003 | 3RD PARTY REVIEW-COMMERCIAL | 08/01/2003 | COMPLETED |
| 09/10/2003 | 3RD PARTY REVIEW-COMMERCIAL | 09/17/2003 | COMPLETED |
| 09/24/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 10/14/2004 | COMPLETED |
| 09/25/2003 | 3RD PARTY REVIEW-COMMERCIAL | 10/01/2003 | COMPLETED |
| 10/13/2004 | 3RD PARTY REVIEW-REVISION/OTHER-2ND | 10/14/2004 | COMPLETED |
| 10/15/2003 | 3RD PARTY REVIEW-COMMERCIAL | 10/27/2003 | COMPLETED |
| 10/27/2003 | 3RD PARTY REVIEW-COMMERCIAL | 12/02/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM02737
Permit Status: Final
Permit Description: NEW:CONDOS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/04/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM02737
Permit Description: NEW:CONDOS
Total Completed Inspections - 48
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/15/2003 | PLUMBING - BACK WATER VALVE | RMYERS | Approved | IVRS - Inspection 0000* |
| 12/15/2003 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000* |
| 12/15/2003 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000* |
| 12/15/2003 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*/ 1) ABS DWV UNDERGROUND OK. WTR TEST ONE RISER TO TEN FT. 2) NO BACKWTR VALVE AT THIS BLDG. 3) YARDWTR OK. 4) OK TO COVER ALL AREAS. |
| 12/29/2003 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 12/29/2003 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 12/29/2003 | ELECTRIC - UNDERGROUND | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 12/29/2003 | ELECTRIC - UFER | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 12/30/2003 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 12/30/2003 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 12/30/2003 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 05/10/2004 | ROOF NAILING | HLEYVA | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 05/10/2004 | EXT METAL CLIPS/EXT SHEATHING | HLEYVA | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 05/24/2004 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :*/ NO ABOVE CEILING. |
| 05/24/2004 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* |
| 05/24/2004 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :*/ 1) ABS DWV THRU ROOF OK. WATER TEST OK 2) PEX WATER OK 3) CLOSET FLANGES OK 4) TUBS OK 5) OK TO COVER ALL AREAS |
| 06/07/2004 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/09/2004 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/10/2004 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/10/2004 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/25/2004 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 09/10/2004 | RIGHT OF WAY - FINAL | MOTERO | Approved | TEMP ONLY UNDER P I A |
| 09/15/2004 | ELECTRIC - TEMP POWER FOR TEST | MCAPISTR | Approved | IVRS - Inspection :* |
| 09/16/2004 | LANDSCAPE - FINAL | ACONNOR | Approved | For approval complete site-work and landscape per plan. |
| 09/17/2004 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 09/17/2004 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
| 09/17/2004 | FIRE - FINAL | LTHOMAS | Approved | |
| 09/17/2004 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
| 09/17/2004 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 09/20/2004 | TEP CLEARANCE - AM | JKOZUCH | Approved | PER LHN BOND POSTED |
| 09/20/2004 | ENGINEERING - FINAL | JBRUCKME | Approved | TEMPORARY C OF O APPROVED. 1. PERMANENT C OF O NOT TO BE GIVEN UNTIL THE FINAL GRADING INSPECTION #09190 FOR T03BU00115 IS COMPLETED AND APPROVED. 2. BARRICADE ALL AREAS WHERE ON-GOING CONSTRUCTION ACTIVITY IS OCCURRING TO PREVENT PEDESTRIAN ACCESS. 3. CALL DAVID ROBERTS (349-7643) REGARDING THE TIME SCHEDULE FOR THE COMPLETION OF THE COVERED PARKING AREAS. THIS PARKING LOT MUST BE BARRICADED TO PREVENT PEDESTRIAN ACCESS WHEN CONSTRUCTION IS OCCURRING. |
| 09/20/2004 | TEP CLEARANCE - PM | JKOZUCH | Approved | ECO BOND POSTED PER TAMMY UNITS 100, 101, 102, 103, 201, 202 |
| 10/05/2004 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | PER MECH FINAL |
| 10/05/2004 | MECHANICAL - PROGRESS | CWILLIAM | Approved | PER MECH FINAL |
| 10/05/2004 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | PER MECH FINAL |
| 10/05/2004 | MECHANICAL - UNDERGROUND | CWILLIAM | Approved | PER MECH FINAL |
| 10/05/2004 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 10/06/2004 | PLUMBING - TEMP POWER FOR TEST | RMYERS | Approved | PER PLUM FINAL |
| 10/06/2004 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :*/PLBG FINAL OK. OK FOR C/O PENDING ANY OTHER INSPECTION |
| 10/06/2004 | OUTDOOR LIGHTING FINAL | RMAJUTA | Approved | IVRS - Inspection :* |
| 10/06/2004 | ELECTRIC - PROGRESS | RMAJUTA | Approved | IVRS - Inspection :* |
| 10/06/2004 | SIGN - FINAL | RDEAR | Approved | IVRS - Inspection :* |
| 10/07/2004 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection :* |
| 10/08/2004 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection :* |
| 10/20/2004 | BUILDING - TEMP POWER FOR TEST | HLEYVA | Approved | PER BU FINAL |
| 10/20/2004 | REINFORCED MASONRY PRE-GROUT | HLEYVA | Approved | PER BU FINAL |
| 10/20/2004 | BUILDING - FINAL | HLEYVA | Approved | IVRS - Inspection :*/ 1) ALL UNITS |
| 08/08/2005 | NPPO - FINAL | ACONNOR | Approved |