Permit: T03CM02669
Permit Details
Apply Date:
06/02/2003
Applicant:
BETTER WAY SERVICES INC ,
Description:
REPAIR:FIRE DAMAGE T03VL00445
Contractors:
- BETTER WAY SERVICES INC ,
Permit Reviews
Permit Number - T03CM02669
Permit Status: Final
Permit Description: REPAIR:FIRE DAMAGE T03VL00445
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/15/2004 | REVISION | 03/15/2004 | COMPLETED |
06/02/2003 | RESIDENTIAL BLDG/ZONING | 06/30/2003 | COMPLETED |
06/30/2003 | OTHER | 07/28/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM02669
Permit Status: Final
Permit Description: REPAIR:FIRE DAMAGE T03VL00445
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/02/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM02669
Permit Description: REPAIR:FIRE DAMAGE T03VL00445
Total Completed Inspections - 14
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/12/2003 | MECHANICAL - FINAL | HPEDROZA | Approved | IVRS - Inspection 0999* |
11/12/2003 | MECHANICAL - INTERMEDIATE | HPEDROZA | Approved | IVRS - Inspection 0999* |
11/12/2003 | PLUMBING - INTERMEDIATE | HPEDROZA | Approved | IVRS - Inspection 0999* |
11/12/2003 | ELECTRIC - SERVICE UPGRADE | HPEDROZA | Approved | IVRS - Inspection 0999* |
11/12/2003 | ELECTRIC - INTERMEDIATE | HPEDROZA | Approved | IVRS - Inspection 0999*/ 1) PROVIDE FIRE BLOCK THROUGHOUT 2) EXPOSE NORTH AND WEST WALL STUDS SEMM TO BE INBEDED IN CONCRETE. NO GREEN PLATE 3) SMOKE DETECTORS MUST BE 36" AWAY FROM REGISTERS 4) PROVIDE GREEN PLATE THROUGHOUT 5) NAIL PROTECT ELECTRICAL WIRES WITHIN 1 1/4" FROM EDGE OF STUD 6) NORTH EXTERIOR WALL NOT SECURED 7) STOPPED INSPECTION |
12/23/2003 | FRAMING | HCAMPBEL | Approved | IVRS - Inspection 0000*/ COURTESY ONLY. - ADVISED PROPERTY REP. TO REVISE STRUCTURAL AND SERVICE PANEL MOUNTING AND RE-SUBMIT FOR APPROVAL BY C.O.T. |
03/18/2004 | ROOF NAILING | HCAMPBEL | Approved | IVRS - Inspection 0000* |
03/22/2004 | STUCCO MESH | HCAMPBEL | Approved | IVRS - Inspection 0000* |
03/24/2004 | TEP CLEARANCE - PM | SREEVES | Approved | |
04/01/2004 | SHEET ROCK NAILING | JRIVA | Approved | IVRS - Inspection 0000* |
05/27/2004 | PERMIT FINALED | ROHAVER | Approved | |
05/27/2004 | PLUMBING - FINAL | ROHAVER | Approved | IVRS - Inspection :* |
05/27/2004 | ELECTRIC - FINAL | ROHAVER | Approved | IVRS - Inspection :* |
05/27/2004 | BUILDING - FINAL | ROHAVER | Approved | IVRS - Inspection :* |