Permit: T03CM02357
Permit Details
Apply Date:
05/15/2003
Applicant:
ARCHITECTURAL DESIGN GROUP
Description:
TI:RETAIL
Contractors:
- DIVISION II CONSTRUCTION COMPANY
Permit Reviews
Permit Number - T03CM02357
Permit Status: Final
Permit Description: TI:RETAIL
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/15/2003 | PLANS OK TO SUBMIT - 3RD PARTY | 05/15/2003 | COMPLETED |
05/15/2003 | 3RD PARTY REVIEW-COMMERCIAL TI | 05/23/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM02357
Permit Status: Final
Permit Description: TI:RETAIL
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/15/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM02357
Permit Description: TI:RETAIL
Total Completed Inspections - 20
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/03/2003 | REINFORCED MASONRY PRE-GROUT | RSUBA | Approved | IVRS - Inspection 0000* |
06/04/2003 | FRAMING | RSUBA | Approved | IVRS - Inspection 0000* |
06/05/2003 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0000*/ 1) OK WALLS |
06/09/2003 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000* |
06/09/2003 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000*/ 1) OK TO PROCEED WITH GRID AND CEILING TILES |
06/09/2003 | SHEET ROCK NAILING | RSUBA | Approved | IVRS - Inspection 0000* |
06/13/2003 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000* |
06/16/2003 | FIRE - FINAL | LTHOMAS | Approved | |
06/16/2003 | FIRE SPKLR - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
06/17/2003 | BUILDING ABOVE CEILING | RSUBA | Approved | IVRS - Inspection 0000* |
06/20/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* EXISTING ROOF TOP A/C UNIT AND CONDENSER REMAIN IN USE. |
06/24/2003 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | |
06/24/2003 | ENGINEERING - FINAL | DROBERTS | Approved | |
06/25/2003 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000* |
06/25/2003 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000*/ 1) REPAIR COUPLING REPLACED WITH CXC COUPLING 2) PLUMBING FINAL OK 3) OK FOR C OF O PENDING ANY OTHER INSPECTION |
06/30/2003 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection 0000*/ 1) OK FINAL |
06/30/2003 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection 0000* |
07/02/2003 | SIGN - FINAL | JYBARRA | Approved | |
07/25/2003 | PERMIT FINALED | RSUBA | Approved | |
07/25/2003 | BUILDING - FINAL | RSUBA | Approved | IVRS - Inspection 0000* |