Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
04/28/2003
Applicant:
U S HOME OF ARIZONA *P
Description:
SFR:TD#15-12-36
Contractors:
  • U S HOME OF ARIZONA *P

Permit Reviews

Permit Number - T03CM02049
Permit Status: C of o
Permit Description: SFR:TD#15-12-36
Start Date Submittal Complete Date Status  
04/28/2003 RESIDENTIAL BLDG/ZONING/ENGINE 05/08/2003 COMPLETED Review Details
07/02/2003 REVISION 07/07/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM02049
Permit Status: C of o
Permit Description: SFR:TD#15-12-36
Total Outstanding Activity Conditions - 1
Date Name
04/28/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T03CM02049
Permit Description: SFR:TD#15-12-36
Total Completed Inspections - 23
Date Description Inspector Results Comments
07/09/2003 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection 0000*
07/09/2003 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection 0000*
07/09/2003 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection 0000* 1' DISCREPANCY ON EAST SIDE SET BACK, CHECK SETBACK ON PLOT PLAN FOR HOUSE TO EAST. WILL NEED TO HAVE REVISED PLOT PLAN AT NEXT INSP
07/11/2003 ELECTRIC - UFER RFREIDIN Approved IVRS - Inspection 0000*
07/11/2003 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection 0000*
07/11/2003 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection 0000*
07/28/2003 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved IVRS - Inspection 0000*SENT TO TEP ON 7/29AM
07/28/2003 ELECTRIC - CABLE DROP RFREIDIN Approved IVRS - Inspection 0000*SENT TO TEP ON 7/29AM
08/01/2003 ROOF NAILING RFREIDIN Approved IVRS - Inspection 0000*
08/01/2003 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection 0000*
08/15/2003 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
08/15/2003 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
08/15/2003 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
08/15/2003 FRAMING RFREIDIN Approved IVRS - Inspection 0000*
08/18/2003 STUCCO MESH RFREIDIN Approved IVRS - Inspection 0000*
08/19/2003 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection 0000*
08/26/2003 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection 0000*
09/30/2003 PERMIT FINALED RFREIDIN Approved
09/30/2003 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection 0000*
09/30/2003 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection 0000*
09/30/2003 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection 0000*SENT TO TEP 10/01/03 9:15 am
09/30/2003 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection 0000*
09/30/2003 U VALUE FOR WINDOW RFREIDIN Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW
None CERT OF OCC VIEW