Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Address:
2209 N TUCSON BL
Apply Date:
03/11/2003
Applicant:
DEVLIN GARY P & DEVLIN BRIAN C J
Description:
ADDN: FAMILY ROOM AND PORCH

Permit Reviews

Permit Number - T03CM01247
Permit Status: Expired
Permit Description: ADDN: FAMILY ROOM AND PORCH
Start Date Submittal Complete Date Status  
03/11/2003 RESIDENTIAL BLDG/ZONING/FLOOD 05/12/2003 COMPLETED Review Details
06/16/2003 3RD PARTY REVIEW-RESIDENTIAL 06/30/2003 COMPLETED Review Details
07/16/2003 3RD PARTY REVIEW-RESIDENTIAL 08/08/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM01247
Permit Status: Expired
Permit Description: ADDN: FAMILY ROOM AND PORCH
Total Outstanding Activity Conditions - 1
Date Name
03/11/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T03CM01247
Permite Description: ADDN: FAMILY ROOM AND PORCH
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
SHEET ROCK NAILING N/A Not Inspected
BUILDING - FINAL N/A Not Inspected
ELECTRIC - FINAL N/A Not Inspected
PLUMBING - FINAL N/A Not Inspected
MECHANICAL - FINAL N/A Not Inspected

Completed Inspections

Permit Status: Expired
Permit Number: T03CM01247
Permit Description: ADDN: FAMILY ROOM AND PORCH
Total Completed Inspections - 13
Date Description Inspector Results Comments
06/29/2004 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection :*/ 1) 2" VTR REQUIRED FOR TOILET, VENT THE TRAP ARM NOT THE TRUNK LINE IN FLAT VENTING ROOL THE WYE, OR COMBO UP PAST THE ? OF HORIZONTAL TRUNK 2) LAV/NOT VENT CORRECTLY, YOU CAN USE A A/A VALVE 3) NEED 2 WAY CLEANOUT MAINTAIN 1/4" PER FT SLOPE ON DRAINAGE PIPE USE A FENCO BAND AT CLAY PIPE TO ABS 4) RAISE ALL REBAR ABOVE GRD 5) DOUBLE FOOTINGS 12" BELOW GRADE
06/29/2004 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection :*
06/30/2004 PLUMBING - SEWER HCS CONNECT BSTEVENS Approved
06/30/2004 PLUMBING - ROUGH, SOIL BSTEVENS Approved IVRS - Inspection :*
12/23/2005 U VALUE FOR WINDOW DQUINN Approved IVRS - Inspection :*
08/31/2006 FRAMING CRUIZ Approved IVRS - Inspection :*
09/06/2006 EXT METAL CLIPS/EXT SHEATHING RCAMACHO Approved IVRS - Inspection :*
COMPLY WITH DETAIL 5/6 @ INTERMEDIATE FRAME
CLIPS AND AB'S
09/06/2006 ROOF NAILING RCAMACHO Approved IVRS - Inspection :*
02/19/2014 STUCCO MESH JMILITEL Approved SEAL AROUND ALL PENETRATIONS THROUGH STUCCO. WILL CHECK ON FINAL.
02/19/2014 STUCCO MESH JMILITEL Approved IVRS - Inspection :*
06/18/2014 ELECTRIC - INTERMEDIATE BSTEVENS Approved
06/18/2014 PLUMBING - INTERMEDIATE BSTEVENS Approved
06/18/2014 MECHANICAL - INTERMEDIATE BSTEVENS Approved