Permit: T03CM00072
Permit Details
Apply Date:
01/08/2003
Applicant:
B C CONSTRUCTION INC ,
Description:
TI:OFFICE
Contractors:
- B C CONSTRUCTION INC ,
Permit Reviews
Permit Number - T03CM00072
Permit Status: C of o
Permit Description: TI:OFFICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/08/2003 | COMMERCIAL TI | 01/22/2003 | COMPLETED |
| 01/31/2003 | REVISION | 02/06/2003 | COMPLETED |
| 02/14/2003 | REVISION | 04/29/2003 | COMPLETED |
| 05/12/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 05/14/2003 | COMPLETED |
| 06/03/2003 | REVISION | 06/03/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM00072
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/08/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM00072
Permit Description: TI:OFFICE
Total Completed Inspections - 29
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/19/2003 | ELECTRIC - UFER | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 02/26/2003 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 03/12/2003 | PLUMBING - GAS RECONNECT | RMYERS | Approved | IVRS - Inspection 0000*GAS RECONNECT SHOULD BE GAS PRESSURE TEST. PRESSURE TEST OK PIPING OK OK TO COVER. 2.) PLUMBING INTERMEDIATE OK CLOSET FLANGES OK 3.) OK TO COVER ALL AREAS. |
| 03/12/2003 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000* |
| 03/13/2003 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 03/18/2003 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 03/18/2003 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 04/07/2003 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 04/29/2003 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000* |
| 04/29/2003 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*ABOVE CEILING OK. |
| 04/29/2003 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 04/29/2003 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 04/29/2003 | FRAMING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 04/29/2003 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 04/30/2003 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 05/07/2003 | MECHANICAL - PROGRESS | CWILLIAM | Approved | |
| 05/07/2003 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection 0000* |
| 05/07/2003 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 05/08/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 05/15/2003 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*1 1/2" 009 M2 79070 1.) PLUMBING FINAL OK PENDING VERIFICATION OF BACKFLOW CERTIFICATION. 2.) OK FOR C OF O PENDING ANY OTHER INSPECTION. |
| 05/15/2003 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection 0000*SENT TO TEP ON 5/16/03 AT 9:15AM. |
| 05/16/2003 | RIGHT OF WAY - FINAL | MOTERO | Approved | |
| 05/28/2003 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
| 05/30/2003 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
| 06/03/2003 | OUTDOOR LIGHTING FINAL | MCAPISTR | Approved | |
| 06/04/2003 | ENGINEERING - FINAL | JBRUCKME | Approved | |
| 06/04/2003 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 06/05/2003 | PERMIT FINALED | AQUIROZ | Approved | |
| 06/05/2003 | BUILDING - FINAL | AQUIROZ | Approved |