Permit: T03BU02422
Permit Details
Apply Date:
09/19/2003
Applicant:
RICK ENGINEERING
Description:
GRADING:566CY CUT & 3025CY FILL
Contractors:
- TANQUE VERDE EQUIPMENT CONT. *C
Permit Reviews
Permit Number - T03BU02422
Permit Status: Expired
Permit Description: GRADING:566CY CUT & 3025CY FILL
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/19/2003 | PLANS OK TO SUBMIT - GRADING | 09/19/2003 | COMPLETED |
| 09/19/2003 | GRADING | 11/12/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03BU02422
Permit Status: Expired
Permit Description: GRADING:566CY CUT & 3025CY FILL
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 09/19/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 10/17/2003 | |
| 10/17/2003 | The "As Built" grading plan submitted is approved for purposes of re-activating the original grading permit (# T01BU02435) for continuing final inspections and ultimately release of assurances. Call DSD Engineering Division Inspector for request for final inspection(s). |
Outstanding Inspections
Permit Status: Expired
Permit Number: T03BU02422
Permite Description: GRADING:566CY CUT & 3025CY FILL
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/18/2003 | GRADING - FINAL | N/A | Denied | 1. Handicapped access ramps and sidewalks on the south side of the project have been eliminated on the revised grading plan. These ramps and sidewalks are required per the Tentative Plat. 2. Provide the curb at the east side of the the handicap ramp adjacent to Basin A as shown in Detail D, Page 4 3. Provide details that show the drainage flow thru the walls in/out of the Water Harvest Basins on the southeast and southwest corners of the project. There are (3) locations with (6) drainage blocks each and (1) location southeast of Lot #22 with a weir wall opening. 4. Re-grade the drainage East of Lot #22 to provide positive flow from the Water Harvest Basin into Basin A. 5. Re-grade the the East Channel to the specifications shown in Detail E, Page 2. Provide the 8' drainage swale with 3:1 side slopes. 6. Re-grade the Water Harvest Areas at the north perimeter to the specification in Detail B, Page 2. Provide a 5' wide area with 3:1 side slopes. 7. The weir wall at Basin C is not constructed to the specifications in Detail D, Page 2. Provide an as-built Detail. 8. Provide a 3' wide flat area at the top of slope on the south side of Basin C adjacent to Lot # 4 as shown in Detail C, Page 2. 9. Re-grade the Water Harvest Basin at the southwest corner of the site. Remove the excess soil and provide 4:1 side slopes as shown on the plan. 10. Regrade Basin B and remove the excess soil from the south west portion of the basin and slope. Provide the 5.5' sidewalk on the north side of the basin as shown in Detail A, Page 2. 11. Provide (2) survey monuments in Teton Rd at the center of each new street. 12. Submit a revised Grading Plan (with all modifications) to the City of Tucson Development Services Department for review and approval by Engineering and Zoning Divisions 13. Provide ADA approved slope at handicap ramp west of Basin A 14.Extend sidewalks to R.O.W. adjacent to Lots 1,6,17 &18. 15. Provide RLS spot elevations, verify along east and south perimeters, and southwest corner of the project and the top of the basins. 16. Verify Detail A, Page 2 for placement of wall, property line and 3:1 slope. 17. Provide "No Parking" signs as required. |
Completed Inspections
Permit Status: Expired
Permit Number: T03BU02422
Permit Description: GRADING:566CY CUT & 3025CY FILL
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/15/2003 | LANDSCAPE INSPECTION | PGILBERT | Approved |