Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
3726 E CONCORD SV
Apply Date:
04/03/2002
Applicant:
ARIZONA PLUMBING SERVICES, DBA SEARS,*C
Description:
REPLACE:WATERHEATER(APA)
Contractors:
  • ARIZONA PLUMBING SERVICES, DBA SEARS,*C

Outstanding Activity Conditions

Permit Number - T02PL00738
Permit Status: Expired
Permit Description: REPLACE:WATERHEATER(APA)
Total Outstanding Activity Conditions - 1
Date Name
04/03/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T02PL00738
Permite Description: REPLACE:WATERHEATER(APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
05/15/2002 PLUMBING - FINAL N/A Denied IVRS - Inspection 0999*/ 1) MUST HAVE 1" MINIMUM CLEARANCE AROUND VENT PIPE 2) DO NOT SEAL BOTTOM OF DOUBLE WALL VENT PIPE 3) TPRV DISCHARGE LINE MUST SLOPE OF 1/4" PER FT. DOWNWARD 4) COLD WATER SHUT OFF VALVE IS INOPERATIONAL

Documents

File Name Document Type  
T02PL00738 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW