Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Apply Date:
02/27/2002
Applicant:
ARIZONA PLUMBING SERVICES, DBA SEARS,*C
Description:
REPLACE:WATER HEATER (APA)
Contractors:
  • ARIZONA PLUMBING SERVICES, DBA SEARS,*C

Outstanding Activity Conditions

Permit Number - T02PL00515
Permit Status: Expired
Permit Description: REPLACE:WATER HEATER (APA)
Total Outstanding Activity Conditions - 1
Date Name
02/27/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T02PL00515
Permite Description: REPLACE:WATER HEATER (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
05/08/2002 PLUMBING - FINAL N/A Denied IVRS - Inspection 0999*/ 1) HORIZONTAL SECTION OF TPRV DISCHARGE LINE DOES NOT HAVE 1/4" PER FT DOWNWARD SLOPE 2) NEED 1" CLEARANCE, MINIMUM ALL AROUND VENT PIPE FROM DRYWALL 3) VENT PIPE NOT PROPERLY CONNECTED TO THE VENT CONNECTOR 4) DO NOT SEAL THE SPACE BETWEEN THE INNER AND OUTER WALLS OF THE VENT PIPING 5) ANCHOR VENT PIPE TO VENT CONNECTOR WITH 3 SCREWS