Permit: T02PL00480
Permit Details
Apply Date:
02/22/2002
Applicant:
A AND R PLUMBING INC
Description:
GAS:RECONNECT
Contractors:
- A AND R PLUMBING INC
Outstanding Activity Conditions
Permit Number - T02PL00480
Permit Status: Expired
Permit Description: GAS:RECONNECT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/22/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T02PL00480
Permite Description: GAS:RECONNECT
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/21/2002 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection 0999*1.) FLEX CONNECTOR AT WATER HEATER EXCEEDS ALLOWABLE LENGTH. 2.) CAP OR PLUG OFF EXISTING ABANDONED GAS LINE. 3.) REPAIR DAMAGED COMBUSTION RELIEF DUCT 4.) T & P RELIEF NOT APPROVED. |
Completed Inspections
Permit Status: Expired
Permit Number: T02PL00480
Permit Description: GAS:RECONNECT
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/26/2002 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000*1.) GAS PRESSURE TEST OK 2.) ALL VALVES TO E AGA OR CSA APPROVED. 3.) CONNECTIONS AT WATER HEATER AND FURNANCE NOT APPROVED. REVIEW CHAPTER 12, GAS INCLUDING FLEX CONNECTORS VALVES 4.) T & P RELIEF DRAIN MISSING. |