Permit: T02PL00087
Permit Details
Apply Date:
01/11/2002
Applicant:
MONTANO VICENTE & MARTHA JT/RS
Description:
REPAIR:GAS LINE
Permit Reviews
Permit Number - T02PL00087
Permit Status: Final
Permit Description: REPAIR:GAS LINE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/11/2002 | PLUMBING | 01/11/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02PL00087
Permit Status: Final
Permit Description: REPAIR:GAS LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/11/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T02PL00087
Permit Description: REPAIR:GAS LINE
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/18/2002 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*1.) UNDERGROUND LEAK REPAIRED WITH SCOTCHCOAT THE REST OF THE UNDERGROUND IS BLK IRON PIPE. OWNER AWARE THAT UNCOATED PIPE MAY FAIL.2.) TWO UNIONS IN EXISTING LINE. PRESSURE TEST HOLDING 10#. 3.) IF 1/2" UNDERGROUND FAILS REMOVE UNIONS AND USE RIGHT LEFT NIPPLE AND COUPLING 4.) OK FOR GAS 5.) UCC LEFT AT METER. |
| 01/18/2002 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000* |
| 01/18/2002 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000* |