Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T02EL00069
Permit Details
Apply Date:
01/10/2002
Applicant:
TRENT DURAN
Description:
UPGRADE:ELECTRIC
Permit Reviews
Permit Number - T02EL00069
Permit Status: Final
Permit Description: UPGRADE:ELECTRIC
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/10/2002 | ELECTRICAL | 01/10/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02EL00069
Permit Status: Final
Permit Description: UPGRADE:ELECTRIC
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
01/10/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T02EL00069
Permit Description: UPGRADE:ELECTRIC
Total Completed Inspections - 2
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/12/2002 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000*1.) INSTALL BOND BUSHING ON RISER CONDUIT WHERE USING CONCENTRIC WITHOUT HUB 250-96 N.E.C. 2.) INSTALL (2) PER 250 N.E.C. GROUND RODS 6' MIN APART. 3.) INSTALL PERMANENT ADDRESS LABEL. 4.) I.D. CIRCUIT BREAKERS TEP CHRIS Y. TOLD OWNER THAT EXISTING GROUNDING OK. |
02/12/2002 | ELECTRIC - SERVICE UPGRADE | JORTA | Approved | IVRS - Inspection 0000* |