Permit: T02CM05278
Permit Details
Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
3754 N PLACITA VERGEL
Address NEW:
3754 N PLACITA VERGEL
Apply Date:
11/14/2002
Applicant:
NEW WEST DEVELOPMENT
Description:
SFR:TD# 15-47-35
Contractors:
- PATHWAY DEVELOPMENTS INC ,
Outstanding Activity Conditions
Permit Number - T02CM05278
Permit Status: C of o
Permit Description: SFR:TD# 15-47-35
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/14/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM05278
Permit Description: SFR:TD# 15-47-35
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/14/2003 | REINFORCED MASONRY PRE-GROUT | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 01/15/2003 | PLUMBING - SEWER HCS CONNECT | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 01/15/2003 | PLUMBING - ROUGH, SOIL | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 01/17/2003 | PLUMBING - YARD WTR LINE/TEST | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 01/23/2003 | ELECTRIC - UFER | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 01/23/2003 | BUILDING PRE-SLAB | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 01/23/2003 | EXCAVATION/LAYOUT REBAR & ZON | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 02/25/2003 | ROOF NAILING | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 03/13/2003 | EXT METAL CLIPS/EXT SHEATHING | FGREER | Approved | IVRS - Inspection 0000* |
| 03/18/2003 | MECHANICAL - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 03/18/2003 | PLUMBING - GAS PRESSURE TEST | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 03/18/2003 | ELECTRIC - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 03/20/2003 | PLUMBING - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 03/20/2003 | FRAMING | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 03/28/2003 | SHEET ROCK NAILING | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 03/28/2003 | U VALUE FOR WINDOW | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 03/28/2003 | STUCCO MESH | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 04/28/2003 | ELECTRIC - TEMPORARY SERVICE | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 04/28/2003 | ELECTRIC - CABLE DROP | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 06/26/2003 | PERMIT FINALED | BSTEVENS | Approved | |
| 06/26/2003 | MECHANICAL - FINAL | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 06/26/2003 | PLUMBING - FINAL | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 06/26/2003 | ELECTRIC - FINAL | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 06/26/2003 | BUILDING - FINAL | BSTEVENS | Approved | IVRS - Inspection 0000* |