Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address NEW:
207 W PENNSYLVANIA DR
Apply Date:
11/06/2002
Applicant:
JOHNSON GENE E & RUTH N JT/RS
Description:
ADDITION:DEN

Permit Reviews

Permit Number - T02CM05171
Permit Status: Expired
Permit Description: ADDITION:DEN
Start Date Submittal Complete Date Status  
01/05/2005 REVISION 01/07/2005 COMPLETED Review Details
11/06/2002 RESIDENTIAL BLDG/ZONING/FLOOD 11/07/2002 COMPLETED Review Details
11/07/2005 REVISION - WALK THRU 11/07/2005 COMPLETED Review Details
12/11/2003 REVISION 12/11/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM05171
Permit Status: Expired
Permit Description: ADDITION:DEN
Total Outstanding Activity Conditions - 1
Date Name
11/06/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T02CM05171
Permite Description: ADDITION:DEN
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
ELECTRIC - FINAL N/A Not Inspected
PLUMBING - FINAL N/A Not Inspected
07/06/2005 BUILDING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
12/12/2003 MECHANICAL - FINAL N/A Partial Approval IVRS - Inspection 0000*

Completed Inspections

Permit Status: Expired
Permit Number: T02CM05171
Permit Description: ADDITION:DEN
Total Completed Inspections - 15
Date Description Inspector Results Comments
11/13/2002 BUILDING PRE-SLAB MTESTER Approved IVRS - Inspection 0000*
11/13/2002 BUILDING PRE-SLAB MTESTER Approved IVRS - Inspection 0999*
11/13/2002 EXCAVATION/LAYOUT REBAR & ZON MTESTER Approved IVRS - Inspection 0000*/ 1) REINSPECT
11/13/2002 EXCAVATION/LAYOUT REBAR & ZON MTESTER Approved IVRS - Inspection 0999*
11/20/2002 PLUMBING - GAS PRESSURE TEST FGREER Approved IVRS - Inspection 0000*
11/20/2002 ROOF NAILING FGREER Approved IVRS - Inspection 0000*
11/20/2002 EXT METAL CLIPS/EXT SHEATHING FGREER Approved IVRS - Inspection 0000*
11/25/2002 STUCCO MESH FGREER Approved IVRS - Inspection 0000*
12/19/2002 FRAMING MTESTER Approved IVRS - Inspection 0000*NEED F/P SP??
CHANGE PLANS TO SHOW CHANGES
REMOVE PAPER FROM ? INSULATION
12/19/2002 MECHANICAL - INTERMEDIATE MTESTER Approved IVRS - Inspection 0000*/ 1) NEED PERMIT FOR WATER HEATER INSTALLATION 2) MECHANICAL APPROVAL FOR NEW ROOM ADDITION ONLY 3) NEED PERMIT FOR WATER HEATER/FURNACE ROOM
12/19/2002 ELECTRIC - INTERMEDIATE MTESTER Approved IVRS - Inspection 0000*
12/12/2003 PLUMBING - INTERMEDIATE ROHAVER Approved 1) INSTALL 90 ELBOW CONDENSATE LINE EXTERIOR. 2) COMPLETE ALL ELECTRIC 3) INSTALL BONDING JUMPER ACCROSS NON-METALIC A.C /FURNACE BELLOWS 4) INSTALL ANTI-SYPHON HOSE BIB 5) INSTALL 90 DEGREE ELBOW EXTERIOR H20 HEATER PTR LINE 6) CANNOT HAVE ELECTRIC ROMEX EXPOSED BELOW * FOOT 7) INSTALL DOORS ON FURNACE, H20 HEATER ?? 8) SEAL CHAISE EXTERIOR FREON LINES.
12/12/2003 SHEET ROCK NAILING ROHAVER Approved IVRS - Inspection 0000*
08/06/2005 STEM WALL/RETAINING WALL EDURAZO Approved IVRS - Inspection :*
09/27/2005 REINFORCED MASONRY PRE-GROUT FVALENCI Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW