Permit: T02CM05082
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
3350 E HEMISPHERE LP
Address NEW:
3350 E HEMISPHERE LP
Apply Date:
11/01/2002
Applicant:
MORROW, KEVIN THOMAS
Description:
TI:OFFICE
Contractors:
- BANNER STRUCTURES
Permit Reviews
Permit Number - T02CM05082
Permit Status: C of o
Permit Description: TI:OFFICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/01/2002 | 3RD PARTY COMMERCIAL TI | 12/09/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM05082
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/01/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM05082
Permit Description: TI:OFFICE
Total Completed Inspections - 18
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/20/2002 | PLUMBING - PROGRESS | RMYERS | Approved | DUE TO ENGINEERING DIFFICULTIES ALL PLUMBING IN PHASE THREE WILL BE ELIMINATED AND RE DEFINED AS PHASE FIVE. CONTRACTOR WANTS TEMP C OF O. TO OCCUPY PHASE THREE EAST SIDE ONLY. CURRENT APPROVED PLAN STILL SHOWS PLUMBING IN PHASE THREE. OK TO OCCUPY UNTIL APPROVAL OF REVISED PLAN. SHELL BLDG. HAS SANITARY FACILITIES. |
| 11/20/2002 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 11/20/2002 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
| 11/26/2002 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | WALL ROUGH IN NW SECTION. U/G TO CONF. RM 1ST FLR. EAST. |
| 12/13/2002 | FIRE - FINAL | LTHOMAS | Approved | PHASE III O.K. FOR TEMP C OF O. |
| 12/13/2002 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
| 12/13/2002 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*1.) NOT READY FOR INSPECTIONS. |
| 12/13/2002 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000*OK TCO 1.) NEED PLUMBING & ELEC FINAL 2.) FIRE & MECHANICAL APPROVED 3.) BUILDING COMPONENTS COMPLETE EGRESS OK. |
| 12/16/2002 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000*PHASE III. |
| 12/19/2002 | FIRE SPKLR - FINAL | LTHOMAS | Approved | AREA "E" IST FLOOR EAST APPROVED FOR C OF O. |
| 04/07/2003 | SIGN - FINAL | JYBARRA | Approved | |
| 04/07/2003 | ENGINEERING - FINAL | JBRUCKME | Approved | |
| 04/07/2003 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000* |
| 04/12/2003 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000* |
| 04/12/2003 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*PLBG FINAL IS OK. |
| 04/17/2003 | PERMIT FINALED | LHANLY | Approved | |
| 04/17/2003 | RIGHT OF WAY - FINAL | STINEO | Approved | |
| 04/17/2003 | PLUMBING - ABOVE CEILING | LHANLY | Approved |