Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
10/29/2002
Applicant:
K B HOME OF TUCSON ****''T''
Description:
SFR:TD#15-44-89
Contractors:
  • K B HOME OF TUCSON ****''T''

Permit Reviews

Permit Number - T02CM05014
Permit Status: C of o
Permit Description: SFR:TD#15-44-89
Start Date Submittal Complete Date Status  
10/29/2002 RESIDENTIAL BLDG/ZONING/FLOOD 10/30/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM05014
Permit Status: C of o
Permit Description: SFR:TD#15-44-89
Total Outstanding Activity Conditions - 1
Date Name
10/29/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T02CM05014
Permit Description: SFR:TD#15-44-89
Total Completed Inspections - 23
Date Description Inspector Results Comments
11/12/2002 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection 0000*
11/19/2002 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection 0000*
11/21/2002 ELECTRIC - UFER RFREIDIN Approved IVRS - Inspection 0000*
11/21/2002 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection 0000*
11/21/2002 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection 0000*
12/31/2002 PLUMBING - SEWER HCS CONNECT JRIVA Approved IVRS - Inspection 0950*
12/31/2002 ROOF NAILING JRIVA Approved IVRS - Inspection 0950*
12/31/2002 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved IVRS - Inspection 0950*/ 1) GARAGE FRONT OSB MUST BE NAILED TO STUDS LOCATED AT 16" ON CENTER 2) GARAGE FRONT CS STRAPS NOT INSTALLED 3) WEDGE ANCHORS NOT ALLOWED SEE S-1 NOTES FOR RETRO FIT BOLTS 4) CS STRAPS TO SHORT OR MISSING SEE 2/SD-2 5) GABLE TRUSSES NOT STRAPPED PER 7/SD-3 6) NO LADDER ACCESS TO ROOF 7) NO TRUSS DRAWINGS 8) NO WATER TEST ON SEWER FROM CLEANOUT TO HCS 9) STOPPED INSPECTION
01/10/2003 PLUMBING - GAS PRESSURE TEST DQUINN Approved IVRS - Inspection 0000*
01/13/2003 MECHANICAL - INTERMEDIATE DQUINN Approved IVRS - Inspection 0000*
01/13/2003 PLUMBING - INTERMEDIATE DQUINN Approved IVRS - Inspection 0000*
01/13/2003 ELECTRIC - INTERMEDIATE DQUINN Approved IVRS - Inspection 0000*
01/13/2003 FRAMING DQUINN Approved IVRS - Inspection 0000*
01/21/2003 SHEET ROCK NAILING DQUINN Approved IVRS - Inspection 0000*
01/21/2003 STUCCO MESH DQUINN Approved IVRS - Inspection 0000*
02/06/2003 ELECTRIC - TEMPORARY SERVICE DQUINN Approved IVRS - Inspection 0000*
02/06/2003 ELECTRIC - CABLE DROP DQUINN Approved IVRS - Inspection 0000*
02/18/2003 PERMIT FINALED DQUINN Approved
02/18/2003 MECHANICAL - FINAL DQUINN Approved IVRS - Inspection 0000*
02/18/2003 PLUMBING - FINAL DQUINN Approved IVRS - Inspection 0000*
02/18/2003 ELECTRIC - FINAL DQUINN Approved IVRS - Inspection 0000*
02/18/2003 BUILDING - FINAL DQUINN Approved IVRS - Inspection 0000*
02/18/2003 U VALUE FOR WINDOW DQUINN Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW