Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T02CM04850
Permit Details
Apply Date:
10/17/2002
Applicant:
HOLGUIN FERNANDO C & ROMELIA C J
Description:
ADDITION: 3 BEDROOMS:2 BATHROOM
Permit Reviews
Permit Number - T02CM04850
Permit Status: Final
Permit Description: ADDITION: 3 BEDROOMS:2 BATHROOM
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/24/2003 | REVISION | 02/24/2003 | COMPLETED |
06/04/2003 | REVISION | 06/04/2003 | COMPLETED |
10/17/2002 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 11/22/2002 | COMPLETED |
12/06/2002 | RESUBMITTAL | 12/19/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM04850
Permit Status: Final
Permit Description: ADDITION: 3 BEDROOMS:2 BATHROOM
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/17/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T02CM04850
Permit Description: ADDITION: 3 BEDROOMS:2 BATHROOM
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/04/2003 | PLUMBING - ROUGH, SOIL | DBRITO | Approved | IVRS - Inspection 0000* |
02/04/2003 | ELECTRIC - UFER | DBRITO | Approved | IVRS - Inspection 0000* |
02/04/2003 | BUILDING PRE-SLAB | DBRITO | Approved | IVRS - Inspection 0000* |
02/04/2003 | STEM WALL/RETAINING WALL | DBRITO | Approved | IVRS - Inspection 0000* |
02/04/2003 | EXCAVATION/LAYOUT REBAR & ZON | DBRITO | Approved | IVRS - Inspection 0000* |
04/04/2003 | ROOF NAILING | FGREER | Approved | IVRS - Inspection 0000* |
04/04/2003 | EXT METAL CLIPS/EXT SHEATHING | FGREER | Approved | IVRS - Inspection 0000* |
05/05/2003 | MECHANICAL - INTERMEDIATE | MTESTER | Approved | IVRS - Inspection 0000* |
05/05/2003 | PLUMBING - ROOF DRAINS | MTESTER | Approved | IVRS - Inspection 0000* |
05/05/2003 | PLUMBING - INTERMEDIATE | MTESTER | Approved | IVRS - Inspection 0000* |
05/05/2003 | U VALUE FOR WINDOW | MTESTER | Approved | IVRS - Inspection 0000* |
05/05/2003 | STUCCO MESH | MTESTER | Approved | IVRS - Inspection 0000* |
06/05/2003 | ELECTRIC - SERVICE RELOCATION | DBRITO | Approved | IVRS - Inspection 0000* |
06/05/2003 | ELECTRIC - INTERMEDIATE | DBRITO | Approved | |
06/20/2003 | SHEET ROCK NAILING | JRIVA | Approved | IVRS - Inspection 0000* |
06/20/2003 | FRAMING | JRIVA | Approved | |
11/23/2004 | BUILDING - FINAL | EDURAZO | Approved | IVRS - Inspection : See detailed listing on site.| 999*/ 1) PROVIDE HAND RAIL AT STAIRWAY 2) REMOVE DBL KEYED DEAD BOLTS AT EXTERIOR DOORS 3) SEAL WATER CLOSET AT TILE |
11/23/2004 | MECHANICAL - FINAL | EDURAZO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
11/23/2004 | PLUMBING - FINAL | EDURAZO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
11/23/2004 | ELECTRIC - FINAL | EDURAZO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
04/08/2005 | PERMIT FINALED | JWEATHER | Approved |