Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T02CM04689
Permit Details
Apply Date:
10/08/2002
Applicant:
MARK WRIGHT CONSTRUCTION''T''
Description:
SFR:TD#15-48-85
Contractors:
- MARK WRIGHT CONSTRUCTION''T''
Permit Reviews
Permit Number - T02CM04689
Permit Status: C of o
Permit Description: SFR:TD#15-48-85
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/08/2002 | RESIDENTIAL BLDG/ZONING/FLOOD | 10/08/2002 | COMPLETED |
11/04/2002 | REVISION | 11/04/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM04689
Permit Status: C of o
Permit Description: SFR:TD#15-48-85
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/08/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM04689
Permit Description: SFR:TD#15-48-85
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/24/2002 | PLUMBING - SEWER HCS CONNECT | JRIVA | Approved | IVRS - Inspection 0000* |
10/24/2002 | PLUMBING - ROUGH, SOIL | JRIVA | Approved | IVRS - Inspection 0000* |
11/05/2002 | ELECTRIC - UFER | JRIVA | Approved | IVRS - Inspection 0000* |
11/05/2002 | BUILDING PRE-SLAB | JRIVA | Approved | IVRS - Inspection 0000* |
11/05/2002 | EXCAVATION/LAYOUT REBAR & ZON | JRIVA | Approved | IVRS - Inspection 0000* |
11/27/2002 | ELECTRIC - TEMPORARY SERVICE | RFREIDIN | Approved | IVRS - Inspection 0000* |
11/27/2002 | ELECTRIC - CABLE DROP | RFREIDIN | Approved | IVRS - Inspection 0000* |
12/20/2002 | MECHANICAL - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
12/20/2002 | PLUMBING - GAS PRESSURE TEST | BSTEVENS | Approved | IVRS - Inspection 0000* |
12/20/2002 | PLUMBING - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
12/20/2002 | ELECTRIC - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
12/20/2002 | FRAMING | BSTEVENS | Approved | IVRS - Inspection 0000* |
12/20/2002 | ROOF NAILING | BSTEVENS | Approved | IVRS - Inspection 0000* |
12/20/2002 | EXT METAL CLIPS/EXT SHEATHING | BSTEVENS | Approved | IVRS - Inspection 0000* |
01/29/2003 | SHEET ROCK NAILING | BSTEVENS | Approved | IVRS - Inspection 0000* |
01/29/2003 | U VALUE FOR WINDOW | BSTEVENS | Approved | IVRS - Inspection 0000* |
01/29/2003 | STUCCO MESH | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/28/2003 | PERMIT FINALED | BSTEVENS | Approved | |
03/28/2003 | MECHANICAL - FINAL | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/28/2003 | PLUMBING - FINAL | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/28/2003 | PLUMBING - YARD WTR LINE/TEST | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/28/2003 | ELECTRIC - FINAL | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/28/2003 | BUILDING - FINAL | BSTEVENS | Approved | IVRS - Inspection 0000* |