Permit Details

Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
4127 E SPRING ST
Apply Date:
09/16/2002
Applicant:
WILHELMI CLAIRE/FORTIER PAUL
Description:
ADDITION:PORCH AT FRONT & CARPORT

Permit Reviews

Permit Number - T02CM04348
Permit Status: Expired
Permit Description: ADDITION:PORCH AT FRONT & CARPORT
Start Date Submittal Complete Date Status  
09/16/2002 RESIDENTIAL BLDG/ZONING 09/16/2002 COMPLETED Review Details
10/03/2002 REVISION 10/04/2002 COMPLETED Review Details
10/08/2002 REVISION 10/08/2002 COMPLETED Review Details
10/22/2002 REVISION 09/12/2003 STOPPED Review Details

Outstanding Activity Conditions

Permit Number - T02CM04348
Permit Status: Expired
Permit Description: ADDITION:PORCH AT FRONT & CARPORT
Total Outstanding Activity Conditions - 1
Date Name
09/16/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T02CM04348
Permite Description: ADDITION:PORCH AT FRONT & CARPORT
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
ROOF NAILING N/A Not Inspected
BUILDING - FINAL N/A Not Inspected

Completed Inspections

Permit Status: Expired
Permit Number: T02CM04348
Permit Description: ADDITION:PORCH AT FRONT & CARPORT
Total Completed Inspections - 4
Date Description Inspector Results Comments
09/24/2002 EXCAVATION/LAYOUT REBAR & ZON JRIVA Approved IVRS - Inspection 0000*
10/08/2002 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
10/08/2002 FRAMING RFREIDIN Approved IVRS - Inspection 0000*/ 1) ELECTRIC USE CORRECT FITTINGS FOR CONNECTING CONDUIT, INSTALL BONDING JUMPER 2) 8" PENETRATION CORBEL TO POST LAG 3 1/2" MINIMUM PENETRATION BEAM TO CORBEL 3) TWO BEARING SITUATIONS WITH OFF SET POST TO BEAM JOINT TWO LAGS ONLY BLOWN TO CORBEL 4) 15" OF EXISTING CARPORT DOUBLE 2 X 6 IS ONLY A SINGLE PLY WITH A BLOCK HANGER 3/4" SUPPORTING BUILT 5) GET APPOVAL ON THESE DETAILS
10/23/2002 ELECTRIC - FINAL JRIVA Approved IVRS - Inspection 0999*/ 1) USE PROPER WIRE RESTRAINTS FOR INSTALLED BOXES 2) GROUND ALL METAL ELECTRIC BOXES WITH APPROVED GREEN GROUND SCREWS. OPEN ALL ELECTRIC BOXES FOR INSPECTION 3) MAKE UP ALL GROUNDS AND SECURE

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW