Permit: T02CM04344
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
6050 S COUNTRY CLUB RD #180
Address NEW:
6050 S COUNTRY CLUB RD #180
Apply Date:
09/13/2002
Applicant:
METRO PERMIT EXPRESS, INC
Description:
TI:OFFICE
Architects:
- MORROW, KEVIN THOMAS
Contractors:
- CHESTNUT CONSTRUCTION CORPORATIO
Permit Reviews
Permit Number - T02CM04344
Permit Status: C of o
Permit Description: TI:OFFICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/13/2002 | COMMERCIAL TI | 11/07/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM04344
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/13/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM04344
Permit Description: TI:OFFICE
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/24/2002 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*ABS UNDERGROUND TO 2 WAY CLEAN OUT OK 2.) WATER TEST ONE RISER TO TEN FEET. 3.) OK TO BACKFILL. |
| 11/26/2002 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000*PLUMBING ABOVE CEILING OK CONDENSATE PIPING TO BE INSPECTED BY MECHANICAL INSPECTOR. 2.) OK TO COVER. |
| 12/04/2002 | FIRE SPKLR - OH PIPING & HYDRO | JEGAN | Approved | IVRS - Inspection 0000*OVERHEAD PRESS TEST OK |
| 12/06/2002 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
| 12/10/2002 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*1.) ABS DWV THRU ROOF OK WATER TEST OK 2.) COPPER WATER PIPING OK PRESSURE TEST OK 3.) CLOSET FLANGES OK 4.) RWL'S OK TO OUTSIDE BLDG. WEST SIDE NEED TO SEE CONTINUATION PAST SIDEWALK 5.) OK TO COVER WALLS AND CEILING. |
| 12/10/2002 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000*WALL ROUGH IN OF OFFICE PARTITIONS. |
| 12/12/2002 | SHEET ROCK NAILING | RSUBA | Approved | IVRS - Inspection 0000* |
| 12/13/2002 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
| 12/13/2002 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 12/27/2002 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000*NOTE!!IF ACCESSABLE I WOULD HOME WANTED TRAPEZE, UNISTRUT W/THREADED ROD UNDER LONG SUPPLY/RETURN DROP. TAKE SHT. MTL STRAP MATL. UNDER EACH DROP ACCROSS BOTTOM, AND CONTINUE UP SIDES 5 FT. CONNECTING TO EXISTING STRAPS. |
| 12/27/2002 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 01/06/2003 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
| 01/06/2003 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) PLBG FINAL IS OK 2.) OK FOR C OF O. |
| 01/09/2003 | ENGINEERING - FINAL | LMAKUS | Approved | |
| 01/09/2003 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000$ |
| 01/09/2003 | FIRE SPKLR - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
| 01/09/2003 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000* |
| 01/10/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 01/10/2003 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000*OK C OF O |
| 01/31/2003 | PERMIT FINALED | JYBARRA | Approved | |
| 01/31/2003 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |