Permit Reviews

Permit Number - T02CM04302
Permit Status: Expired
Permit Description: SFR:NEW
Start Date Submittal Complete Date Status  
02/05/2003 REVISION 02/10/2003 COMPLETED Review Details
02/10/2003 REVISION 02/18/2003 COMPLETED Review Details
09/11/2002 RESIDENTIAL BLDG/ZONING/FLOOD/WWM 10/03/2002 COMPLETED Review Details
10/08/2002 RESUBMITTAL 10/16/2002 COMPLETED Review Details
11/01/2002 REVISION 11/01/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM04302
Permit Status: Expired
Permit Description: SFR:NEW
Total Outstanding Activity Conditions - 2
Date Name
09/11/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
09/12/2002 LANDSCAPE INSPECTOR MUST CHECK FENCING OF NATURAL AREAS PRIOR TO GRUBBING OR GRADING. Call 791-5640 Ext 1140 to schedule.

Outstanding Inspections

Permit Status: Expired
Permit Number: T02CM04302
Permite Description: SFR:NEW
Total Outstanding Inspections - 9
Last Inspection Date Description Inspector Results Comments
REINFORCED MASONRY PRE-GROUT N/A Not Inspected
EXT METAL CLIPS/EXT SHEATHING N/A Not Inspected
ROOF NAILING N/A Not Inspected
STUCCO MESH N/A Not Inspected
U VALUE FOR WINDOW N/A Not Inspected
SHEET ROCK NAILING N/A Not Inspected
ELECTRIC - UNDERGROUND N/A Not Inspected
ELECTRIC - CONSTRUCTION POWER N/A Not Inspected
PLUMBING - ROOF DRAINS N/A Not Inspected

Completed Inspections

Permit Status: Expired
Permit Number: T02CM04302
Permit Description: SFR:NEW
Total Completed Inspections - 20
Date Description Inspector Results Comments
01/14/2003 NPPO PRE PERMIT INSPECTION PGILBERT Approved
04/02/2003 PLUMBING - SEWER HCS CONNECT DBRITO Approved IVRS - Inspection 0000*
04/02/2003 PLUMBING - YARD WTR LINE/TEST DBRITO Approved IVRS - Inspection 0000*
04/02/2003 PLUMBING - ROUGH, SOIL DBRITO Approved IVRS - Inspection 0000*
04/13/2003 ELECTRIC - UFER DBRITO Approved IVRS - Inspection 0000*
04/13/2003 BUILDING PRE-SLAB DBRITO Approved IVRS - Inspection 0000*
04/13/2003 STEM WALL/RETAINING WALL DBRITO Approved IVRS - Inspection 0000*
04/13/2003 EXCAVATION/LAYOUT REBAR & ZON DBRITO Approved IVRS - Inspection 0000*
05/27/2003 MECHANICAL - INTERMEDIATE DBRITO Approved IVRS - Inspection 0000*
05/27/2003 PLUMBING - GAS PRESSURE TEST DBRITO Approved IVRS - Inspection 0000*
05/27/2003 PLUMBING - INTERMEDIATE DBRITO Approved IVRS - Inspection 0000*
05/27/2003 ELECTRIC - INTERMEDIATE DBRITO Approved IVRS - Inspection 0000*
05/27/2003 FRAMING DBRITO Approved IVRS - Inspection 0000*
06/25/2003 ELECTRIC - TEMPORARY SERVICE DBRITO Approved IVRS - Inspection 0000*
06/25/2003 ELECTRIC - CABLE DROP DBRITO Approved IVRS - Inspection 0000*
12/02/2003 MECHANICAL - FINAL DBRITO Approved IVRS - Inspection 0000*
12/02/2003 PLUMBING - FINAL DBRITO Approved IVRS - Inspection 0000*
12/02/2003 PLUMBING - GAS PRESS TEST FNL DBRITO Approved IVRS - Inspection 0000*
12/02/2003 ELECTRIC - FINAL DBRITO Approved IVRS - Inspection 0000*
12/02/2003 BUILDING - FINAL DBRITO Approved IVRS - Inspection 0000*