Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T02CM04219
Permit Details
Apply Date:
09/09/2002
Applicant:
METRO EXPRESS PERMIT
Description:
NEW SHELL BUILDING
Architects:
- GARCIA DAVID V
Contractors:
- CHESTNUT CONSTRUCTION CORPORATIO
Permit Reviews
Permit Number - T02CM04219
Permit Status: Final
Permit Description: NEW SHELL BUILDING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/14/2003 | RESUBMITTAL | 10/15/2003 | COMPLETED |
| 09/09/2002 | 3RD PARTY REVIEW-COMMERCIAL | 10/29/2002 | COMPLETED |
| 10/09/2003 | SITE | 10/15/2003 | COMPLETED |
| 11/14/2002 | RESUBMITTAL | 12/20/2002 | COMPLETED |
| 12/20/2002 | RESUBMITTAL | 02/14/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM04219
Permit Status: Final
Permit Description: NEW SHELL BUILDING
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/09/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T02CM04219
Permit Description: NEW SHELL BUILDING
Total Completed Inspections - 38
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/15/2004 | ELECTRIC - UFER | MCAPISTR | Approved | |
| 04/15/2004 | ELECTRIC - UFER | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 04/23/2004 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :*/ 1) PVC UNDERGROUND OK. TIE-IN TO EXISTING G.C.O. AT 4 PLACES OK. 5# AIR TEST OK. 2) OK TO COVER. |
| 04/26/2004 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/28/2004 | ROOF NAILING | HLEYVA | Approved | IVRS - Inspection :* |
| 07/30/2004 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
| 08/30/2004 | ELECTRIC - TEMPORARY SERVICE | MCAPISTR | Approved | IVRS - Inspection :* |
| 09/15/2004 | TEP CLEARANCE - PM | JKOZUCH | Approved | PER MAC CAPISTRANO ECO |
| 09/24/2004 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 09/24/2004 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
| 09/24/2004 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
| 09/29/2004 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :*/PLANS DO NOT SHOW AN EXACT DESCRIPTION OF WORK. ANY CHANGES WILL BE ADDRESSED BY OWNER ON T.I. INSPECTIONS. OK FOR FINAL ON SHELL ONLY |
| 09/29/2004 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | |
| 09/29/2004 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | |
| 09/29/2004 | FIRE SPKLR - FINAL | LTHOMAS | Approved | OK C OF O |
| 09/29/2004 | FIRE - FINAL | LTHOMAS | Approved | |
| 10/01/2004 | ELECTRIC - UNDERGROUND | RMAJUTA | Approved | |
| 10/01/2004 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | |
| 10/01/2004 | ELECTRIC - CABLE DROP | RMAJUTA | Approved | |
| 10/01/2004 | ELECTRIC - TEMPORARY POLE | RMAJUTA | Approved | |
| 10/01/2004 | ELECTRIC - CONSTRUCTION POWER | RMAJUTA | Approved | |
| 10/01/2004 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* 1) 4 SEWER CONNECTIONS APPROVED ON 042304 BY RMYERS 2) YARD WATER APPROVED FROM METER TO BLDG SHUT OFF UNDER SITE PLUMBING FROM 060602 BY JSTANLEY 3) INTERMEDIATE INSPECTED 071604 BY RMYERS 4) GAS PRESSURE TEST OK 5) PLUMBING FINAL OK. OK FOR C OF O PENDING ?? OTHER INSPECTORS. |
| 10/01/2004 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection :* |
| 10/04/2004 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :*/ 1) 100 A AND B, 120, 130, 140, 150, 160, 170 AND 180 A AND B |
| 10/04/2004 | STEM WALL/RETAINING WALL | AMATHIES | Approved | |
| 10/04/2004 | BUILDING PRE-SLAB | AMATHIES | Approved | |
| 10/04/2004 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | |
| 10/04/2004 | BUILDING ABOVE CEILING | AMATHIES | Approved | |
| 10/04/2004 | U VALUE FOR WINDOW | AMATHIES | Approved | |
| 10/04/2004 | SHEET ROCK NAILING | AMATHIES | Approved | |
| 10/04/2004 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 10/04/2004 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* |
| 10/04/2004 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :* |
| 10/04/2004 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* |
| 10/04/2004 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* |
| 10/04/2004 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* |
| 10/04/2004 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* |
| 10/06/2004 | PERMIT FINALED | JWEATHER | Approved |