Permit: T02CM04204
Permit Details
Apply Date:
09/06/2002
Applicant:
NETZ PENELOPE
Description:
ADDITION:SHED/CARPORT
Permit Reviews
Permit Number - T02CM04204
Permit Status: Final
Permit Description: ADDITION:SHED/CARPORT
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/16/2006 | REVISION - - 1ST | 03/16/2006 | COMPLETED |
09/06/2002 | RESIDENTIAL BLDG/ZONING/FLOOD | 12/30/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM04204
Permit Status: Final
Permit Description: ADDITION:SHED/CARPORT
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
09/06/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T02CM04204
Permit Description: ADDITION:SHED/CARPORT
Total Completed Inspections - 12
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/19/2003 | BUILDING PRE-SLAB | JRIVA | Approved | IVRS - Inspection 0000* |
02/19/2003 | EXCAVATION/LAYOUT REBAR & ZON | JRIVA | Approved | IVRS - Inspection 0000* |
03/13/2003 | REINFORCED MASONRY PRE-GROUT | JRIVA | Approved | IVRS - Inspection 0000* |
08/13/2003 | ROOF NAILING | BSTEVENS | Approved | IVRS - Inspection 0999* 1) ANY ROOF SHEATHING THAT DOES NOT COVER AT LEAST 2 SPANS MUST BE BLOCKED AT EDGES. 2) ADD FHA STRAP AT BEAM CONNECTION TO WALL (E-END). 3) OK TO COVER ROOF. |
05/03/2004 | EXT METAL CLIPS/EXT SHEATHING | BSTEVENS | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
10/26/2004 | ELECTRIC - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection : See detailed listing on site.| 999*/ 1) CEILING BOXES FOR CEILING FAN MUST BE LISTED FOR SUPPORT OF CEILING FAN 2) METAL ELECTRIC BOXES MUST BE GROUNDED 3) PIGTAIL ALL WIRING IN BOXES 4) EXTEND WIRING INTO MAIN PANEL |
10/21/2005 | FRAMING | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) TO BE INSPECTED AFTER ELECTRICAL REVISIONS 2) SECURE ALL ROMEX 8" FROM BOXES 3) CONCEALED BOXES IN CARPORT CEILING 4) ALL BOXES MUST HAVE PROPER CLAMPS AT BOX PENETRATION 5) ADDED OUTLETS AND SWITCHES NOT ON PLAN. BUILD TO PLAN OR SUMBIT REVISION AS BUILT |
08/17/2006 | STUCCO MESH | RCAMACHO | Approved | IVRS - Inspection :* |
10/02/2007 | ELECTRIC - FINAL | DWALKER | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
03/17/2008 | SHEET ROCK NAILING | DWALKER | Approved | IVRS - Inspection :* 1) OK ACTIVITY ROOM |
09/09/2009 | BUILDING - FINAL | DQUINN | Approved | PROGRESS WORK GOING ON |
04/08/2011 | PERMIT FINALED | JWEATHER | Approved |