Permit: T02CM03569
Permit Details
Apply Date:
07/30/2002
Applicant:
PETRICK KEVIN BLAKE
Description:
TI:OFFICE
Contractors:
- STARSYS DEVELOPMENT COMPANY ,
Permit Reviews
Permit Number - T02CM03569
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/30/2002 | COMMERCIAL TI | 08/01/2002 | COMPLETED |
09/27/2002 | REVISION | 10/03/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM03569
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/30/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM03569
Permit Description: TI:OFFICE
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/30/2002 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) P.O.C. OF NEW BLDG. DRAIN TO EXSISTING BLDG. DRAIN IS OK 3.) OK TO BACKFILL TRENCH. |
09/12/2002 | PLUMBING - PROGRESS | TRINIVJR | Approved | IVRS - Inspection 0000* |
09/12/2002 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000* |
09/12/2002 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000*WASTE & VENT SYSTEM IS OK 2.) OVERHEAD WATER DISTRIBUTION IS OK 3.) OK FOR DRYWALL. |
09/12/2002 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000* |
09/13/2002 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
09/19/2002 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
10/03/2002 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | |
10/03/2002 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
10/03/2002 | ENGINEERING - FINAL | LMAKUS | Approved | |
10/03/2002 | FIRE - FINAL | LTHOMAS | Approved | |
10/03/2002 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection 0000* |
10/04/2002 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | |
10/04/2002 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | |
10/04/2002 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000*1.) ABOVE CEILING TRY TO LIFT FLEX DUCT OFF TOP LIGHT FIXTURES. 2.) WHERE DOES FAN COIL CONDENSATE TERMINATE. UNABLE TO FINAL, PLUMBER DIDNT KNOW?? 3.) COMPLETE ELECT. DATA PLATE ON ROOF TOP HEAT PUMP, PERMANENTLY. AUX HT. STRIP? YES? NO? MAYBE? 4.) MAY NEED PROTECTION FROM PARKING VEHICLES. |
10/04/2002 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) PLBG FINAL IS OK 2.) NOTE: SEE ATTACHED SHEET FROM ARCHITECT ACCEPTING ANS. STANDARD. 3.) OK FOR C OF O. |
10/04/2002 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000* |
10/07/2002 | ELECTRIC - SERVICE UPGRADE | DSANTACR | Approved | IVRS - Inspection 0000* |
10/08/2002 | MECHANICAL - FINAL | JMILITEL | Approved | OK FOR C OF O. |
10/11/2002 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000*SENT TO TEP ON 10/14.02 AT 9:15 AM.OK C OF O. OK TO CLEAR. |
10/16/2002 | PERMIT FINALED | AMATHIES | Approved |